WARNING: the use of dampeners for flammable liquids is forbidden if they are made of non-conductive materials that 

charge statically (plastic materials) and without suitable grounding danger of explosion caused by static charges

WARNING: Aggressive, toxic or dangerous liquids may cause serious injuries or damage health, therefore it is forbidden 

to return a dampener containing such products to the manufacturer or to a service center. You must empty the internal 

circuits from the product first and wash and treat it

WARNING: dampeners containing aluminium parts or components coming into contact with the product cannot be used 

to pump iii-trichloroethane, methylene chloride or solvents based on other halogenated hydrocarbons: danger of explo-

sion caused by a chemical reaction

WARNING: the PDA dampeners cannot use with Acetylene, Hydrogen, Carbon disulfide

WARNING: the components of the pneumatic exchanger, including the shaft are made from materials that are not spe-

cifically resistant to chemical products. In case the diaphragm break, replace these elements completely if they have 

come into contact with the product

WARNING: avoid using lubricated and/or un-dried air

WARNING: ascertain that no anomalous noises can be heard during operation. If they occur, stop the dampener imme-

diately

WARNING: ascertain that the fluid at the delivery side does not contain gas. Otherwise stop the dampener immediate

-

ly

WARNING: periodic controls must be made to ensure that there is no powder and/or deposits on the external and inter-

nal surfaces of the dampener and, if necessary, clean them with a damp cloth

WARNING: removal of the air supply pipe must be done when free from powder. Before restarting the dampener, ensure 

that no powder has entered the pneumatic distributor

To replace worn parts, use only original spare parts

However five general elements are important:

A- all the operations must be carried out by skilled personnel or monitored by qualified personal as appropriate

B- implement personal protection works (when the dampener is installed in places involving more than occasional visits) 

against splashes of fluorescent fluid for accidental breakage and conveying works (always) of possible fluid leakages 

towards collection tanks

C- wear acid-resistant clothing and protection whenever operating on the pump

D- make sure that the Intake and delivery valves are correctly closed during the disassembly

E- make sure that there is no supply to the pneumatic circuit during the disassembly

It should be noted that it is very important to realize systems with pipes well arranged, identifiable, suitably equipped 

,with shut-off valves, with comfortable compartments and passages for operators who must inspect their status (since 

the pressure developed by the pump may promote failures to the system if it is of defective construction or worn).

INSTALLATION AND START-UP PERSONNEL

Interventions allowed only to specialised personnel who may eventually delegate to others some operations depending 

on specific evaluations (technical capability required: specialisation in industrial plumbing or electric systems as nee

-

ded).

MAINTENANCE AND OPERATIONAL PERSONNEL

Interventions allowed to general operators (after training on the correct use of the plant):

dampener starting and stopping

•   

opening and closing of valves with the pump at rest

•   

emptying and washing of the pump body via special valves and piping

•   

cleaning of filtering elements

•   

Interventions allowed to qualified personnel (technical capacities required: general knowledge of the mechanical, elec

-

Содержание PDA 100

Страница 1: ...PDA DEALER for Maintenance date of commissioning position system reference service USER MANUAL Part number ...

Страница 2: ...ND USE INSTRUCTIONS 7 INSTALLATION 9 START UP 9 STOP 7 STORAGE INSTRUCTIONS 7 TRANSPORT 9 USE 10 MAINTENANCE 10 DISASSEMBLY 10 INSPECTION 11 SAFETY RULES 12 INSTALLATION AND START UP PERSONNEL 12 MAINTENANCE AND OPERATIONAL PERSONNEL 13 PERSONNEL RESPONSIBLE FOR REPAIRS 13 WASTE DISPOSAL 13 TROUBLESHOOTING AND POSSIBLE CAUSES ...

Страница 3: ...and the user must comply with the instructions contained in the manual and with the current laws Furthermore the user must take into ac count the ignition point of the gases vapors and mists in addition to clouds of combustible powder in the air existing in the area of use II 3 3GD surface equipment used in areas where the presence of gas vapors or mists in addition to clouds of combustible powder...

Страница 4: ...4 4 3 6 a 6 b 5 7 7 2 1 4 3 2 12 6 b 13 14 20 21 22 23 24 4 11 3 2 1 5 5 8 9 10 8 9 10 11 1 MODEL 75 MODEL 100 150 MODEL 200 ...

Страница 5: ...e casing 1 412 1 5 O ring 1 412 2 6 a O ring 1 135 2 6 b Air side diaphragm 1 514 7 Anello di battuta 1 910 2 8 Cap connection 1 488 9 Air side cap 1 260 1 10 Wet side cap 1 182 11 Base optional for 150 2 412 3 12 O ring 2 13 Adaptor fitting 2 910 3 14 connection wet side casing adaptor fitting 2 Pneumatic valve 675 20 Valve body 1 412 4 21 O ring 1 412 5 22 O ring 2 210 23 Probe 1 260 2 24 probe ...

Страница 6: ... fluid have been correctly evaluated The maximum temperature referred to water in continuous operation depends on the version of the materials indicated on the nameplate and on the environment in which the pump will be installed The ambient temperature interval is related to the choice of materials specified on the identification plate OPERATING PRINCIPLE The damper consists of two chambers separa...

Страница 7: ...YES use flexible pipes reinforced with rigid spiral to connect the hydraulic circuit of the pump Rigid piping may cau se strong vibrations and manifolds breaking Do not use pipes with nominal diameter smaller than the diameter of the pump connections For negative installations and or viscous fluids use pipes with greater diameter related to the nominal diameter of the pump 2 YES install and connec...

Страница 8: ...d may enter into the pneumatic circuit and come out from the pump discharge port if the dampener is made from conductive materials and is suitable for flammable products each casing must be equipped with a suitable earthing cable DANGER OF EXPLOSION AND OR FIRE WARNING The dampener must always be grounded irrespective of any organ to which they are connected Lack of grounding or incorrect groundin...

Страница 9: ...and intake height in the delivery circuit check that there are no anomalous vibrations or noise due to the too elastic support structure unsuitable fastening or cavitation after 2 hours of operation stop the pump correctly and check the tightening of all the bolts on the dampener WARNING never start the dampener with the product valves closed danger of diaphragm breakage STOP To stop the pump and ...

Страница 10: ...n must be carried out by qualified personnel use gloves goggles and acid resistant clothing when disconnecting from the system and washing the dampener wash the dampener before carrying out maintenance operations do not disperse the washing waste into the environment DISASSEMBLY Bolts are the type with right thread Clean all the dampner external surfaces using a damp cloth DIAPHRAGMS REMOVAL separ...

Страница 11: ...piping is strong enough and cannot be deformed by the dampener s weight or by the intake Also check that the dampener is not burdened by the weight of the piping if the dampener is to stay in disuse for a long period of time clean it carefully by running a non flammable liquid deter gent through it that is compatible with the dampener s construction materials if the dampener was turned off for a l...

Страница 12: ...wder Before restarting the dampener ensure that no powder has entered the pneumatic distributor To replace worn parts use only original spare parts However five general elements are important A all the operations must be carried out by skilled personnel or monitored by qualified personal as appropriate B implement personal protection works when the dampener is installed in places involving more th...

Страница 13: ...ipment has sufficient flow TROUBLESHOOTING AND POSSIBLE CAUSES trical and chemical features of the plant being fed by the pump and of the pump itself verification of environmental conditions verification of the condition of the liquid being pumped inspections of the control stop devices of the pump inspections of the rotating parts of the dampener trouble shooting PERSONNEL RESPONSIBLE FOR REPAIRS...

Страница 14: ...14 ØA D D K E E ØA In In In In G B B C C F F H H ØA air inlet air inlet air inlet discharge discharge discharge 75 100 150 200 TECHNICAL DATA DIMENSIONS ...

Страница 15: ...t discharge ØA B C D E F G H K 75 3 4 3 8 1 4 120 125 100 1 1 2 1 4 182 175 150 1 1 2 3 8 1 4 231 252 100 328 298 60 345 200 WR FC AL 2 1 2 1 2 350 140 224 153 80 108 405 395 200 SS 2 1 2 1 2 350 114 314 254 80 100 395 390 ...

Страница 16: ...dating of the existing manuals Copyright 2012 ARGAL srl Draw and text total or partial duplication is prohibited MANUFACTURER DATA Production head and legal office Via Labirinto 159 I 25125 BRESCIA Tel 030 3507011 Fax 030 3507077 Administration Tel 030 3507019 Export manager Tel 030 3507022 Customer service Tel 030 3507025 Web www argal it E mail sales argal it CONTRACTUAL DATA medium conc capacit...

Отзывы: