INSTALLATION AND USE INSTRUCTIONS

TRANSPORT

cover the hydraulic connections

•   

lift the hydraulic plastic parts without mechanical stress

•   

for transport on irregular roads, cushion the bumps with suitable support plane

•   

blows and impacts may damage parts that are important for the machine operation and safety

•   

STORAGE INSTRUCTIONS

When is necessari to store the dampeners before installation don’t remove it from the original packaged. The packa-

•   

ged dampeners must be stored lifted from ground level, the ambient must be close, clean and dry.

If at the receipt of the dampeners package seems damaged is necessary to free the dumpner in order to check its 

•   

integry and to store a new package

The place where the dampeners is stored must be closed with an ambient temperature not lower than –5°C and 

•   

not higher than 40°C, the air humidity rate not higher than 80%, the package dampeners mustn’t received shock, 

vibrations and loads rising above.

INSTALLATION

clean the plant before connecting the pump and dampener

•   

make sure that no foreign bodies are left in the dampener. Remove safety caps on the hydraulic connections.

•   

make sure that all of the dampener’s screws are well tightened

•   

position and secure the dampener horizontally

•   

place the pump and the dampener  nearest at the suction point

•   

only fittings with cylindrical gas threads in materials compatible with both the fluid to be pumped and the dampener’s 

•   

construction materials must be used for the connections to the dampener’s collectors

pneumatic supply to the dampener must be made using filtered, died and not lubricated oil free at a pressure of not 

•   

less than 2 bars and not more than 7 bars.

can use the same pneumatic supply of the pump

•   

follow the instructions indicated in the following diagram:

1. YES: use flexible pipes reinforced with rigid spiral to connect the hydraulic circuit of the pump. Rigid piping may cau

-

se strong vibrations and manifolds breaking. Do not use pipes with nominal diameter smaller than the diameter of the 

pump connections. For negative installations and/or viscous fluids use pipes with greater diameter related to the nominal 

diameter of the pump

2. YES: install and connect the pipe downstream from the pulsation dampener. Its diameter must never be smaller than 

the connection. The pipe downstream from the dampener can be rigid and made from material compatible with the fluid 

to be pumped

3. YES: pipe for safety discharge; if the diaphragms are completely torn, the fluid may enter the air circuit damage it, 

and be discharged through the exhaust port. It is therefore necessary that the air exhaust be conveyed by pipes into a 

piping reaching a safe area

4. YES: pipe anchoring; the piping must be sufficiently strong to avoid deformation and must never weigh down on the 

dampener in any way or viceversa

5. YES: shut-off valve of the same diameter as the pump inlet (never smaller) to intercept the fluid correctly in case of 

spills and/or when servicing the pump

6. YES: horizzontal place 

7. NO:  vertical place

8. YES: carry out effective grounding using a suitable size of cable on each pump casing to discharge static currents

9. YES: dampener anchoring

10.YES: trap

11.YES: pressure regulator with gauge

12.YES: check valves on the air supply piping to prevent the pumped liquid from entering the pneumatic circuit if the 

diaphragms are broken is forbidden

13.YES: three-way valve for stop the dampener

14.YES: flow regulator

ensure drainage of fluids which may come out of the dampener

•   

fix the dampener avoid that the pipe weight down up it

•   

arrange for enough room around the dampener for the movements of an operator

•   

inform about the presence of aggressive fluid with suitable coloured labels in accordance with the related standard

•   

Содержание PDA 100

Страница 1: ...PDA DEALER for Maintenance date of commissioning position system reference service USER MANUAL Part number ...

Страница 2: ...ND USE INSTRUCTIONS 7 INSTALLATION 9 START UP 9 STOP 7 STORAGE INSTRUCTIONS 7 TRANSPORT 9 USE 10 MAINTENANCE 10 DISASSEMBLY 10 INSPECTION 11 SAFETY RULES 12 INSTALLATION AND START UP PERSONNEL 12 MAINTENANCE AND OPERATIONAL PERSONNEL 13 PERSONNEL RESPONSIBLE FOR REPAIRS 13 WASTE DISPOSAL 13 TROUBLESHOOTING AND POSSIBLE CAUSES ...

Страница 3: ...and the user must comply with the instructions contained in the manual and with the current laws Furthermore the user must take into ac count the ignition point of the gases vapors and mists in addition to clouds of combustible powder in the air existing in the area of use II 3 3GD surface equipment used in areas where the presence of gas vapors or mists in addition to clouds of combustible powder...

Страница 4: ...4 4 3 6 a 6 b 5 7 7 2 1 4 3 2 12 6 b 13 14 20 21 22 23 24 4 11 3 2 1 5 5 8 9 10 8 9 10 11 1 MODEL 75 MODEL 100 150 MODEL 200 ...

Страница 5: ...e casing 1 412 1 5 O ring 1 412 2 6 a O ring 1 135 2 6 b Air side diaphragm 1 514 7 Anello di battuta 1 910 2 8 Cap connection 1 488 9 Air side cap 1 260 1 10 Wet side cap 1 182 11 Base optional for 150 2 412 3 12 O ring 2 13 Adaptor fitting 2 910 3 14 connection wet side casing adaptor fitting 2 Pneumatic valve 675 20 Valve body 1 412 4 21 O ring 1 412 5 22 O ring 2 210 23 Probe 1 260 2 24 probe ...

Страница 6: ... fluid have been correctly evaluated The maximum temperature referred to water in continuous operation depends on the version of the materials indicated on the nameplate and on the environment in which the pump will be installed The ambient temperature interval is related to the choice of materials specified on the identification plate OPERATING PRINCIPLE The damper consists of two chambers separa...

Страница 7: ...YES use flexible pipes reinforced with rigid spiral to connect the hydraulic circuit of the pump Rigid piping may cau se strong vibrations and manifolds breaking Do not use pipes with nominal diameter smaller than the diameter of the pump connections For negative installations and or viscous fluids use pipes with greater diameter related to the nominal diameter of the pump 2 YES install and connec...

Страница 8: ...d may enter into the pneumatic circuit and come out from the pump discharge port if the dampener is made from conductive materials and is suitable for flammable products each casing must be equipped with a suitable earthing cable DANGER OF EXPLOSION AND OR FIRE WARNING The dampener must always be grounded irrespective of any organ to which they are connected Lack of grounding or incorrect groundin...

Страница 9: ...and intake height in the delivery circuit check that there are no anomalous vibrations or noise due to the too elastic support structure unsuitable fastening or cavitation after 2 hours of operation stop the pump correctly and check the tightening of all the bolts on the dampener WARNING never start the dampener with the product valves closed danger of diaphragm breakage STOP To stop the pump and ...

Страница 10: ...n must be carried out by qualified personnel use gloves goggles and acid resistant clothing when disconnecting from the system and washing the dampener wash the dampener before carrying out maintenance operations do not disperse the washing waste into the environment DISASSEMBLY Bolts are the type with right thread Clean all the dampner external surfaces using a damp cloth DIAPHRAGMS REMOVAL separ...

Страница 11: ...piping is strong enough and cannot be deformed by the dampener s weight or by the intake Also check that the dampener is not burdened by the weight of the piping if the dampener is to stay in disuse for a long period of time clean it carefully by running a non flammable liquid deter gent through it that is compatible with the dampener s construction materials if the dampener was turned off for a l...

Страница 12: ...wder Before restarting the dampener ensure that no powder has entered the pneumatic distributor To replace worn parts use only original spare parts However five general elements are important A all the operations must be carried out by skilled personnel or monitored by qualified personal as appropriate B implement personal protection works when the dampener is installed in places involving more th...

Страница 13: ...ipment has sufficient flow TROUBLESHOOTING AND POSSIBLE CAUSES trical and chemical features of the plant being fed by the pump and of the pump itself verification of environmental conditions verification of the condition of the liquid being pumped inspections of the control stop devices of the pump inspections of the rotating parts of the dampener trouble shooting PERSONNEL RESPONSIBLE FOR REPAIRS...

Страница 14: ...14 ØA D D K E E ØA In In In In G B B C C F F H H ØA air inlet air inlet air inlet discharge discharge discharge 75 100 150 200 TECHNICAL DATA DIMENSIONS ...

Страница 15: ...t discharge ØA B C D E F G H K 75 3 4 3 8 1 4 120 125 100 1 1 2 1 4 182 175 150 1 1 2 3 8 1 4 231 252 100 328 298 60 345 200 WR FC AL 2 1 2 1 2 350 140 224 153 80 108 405 395 200 SS 2 1 2 1 2 350 114 314 254 80 100 395 390 ...

Страница 16: ...dating of the existing manuals Copyright 2012 ARGAL srl Draw and text total or partial duplication is prohibited MANUFACTURER DATA Production head and legal office Via Labirinto 159 I 25125 BRESCIA Tel 030 3507011 Fax 030 3507077 Administration Tel 030 3507019 Export manager Tel 030 3507022 Customer service Tel 030 3507025 Web www argal it E mail sales argal it CONTRACTUAL DATA medium conc capacit...

Отзывы: