p22

M

To revert to measure display.

Reminder:

 

If no key is pressed during 20 s., the 

instrument will revert to measure display.

Note:

 

An exit from mode programming with saving of the confi-

guration will reset the min. and max. values to zero

5.2 Functions which require pressing several keys

:

5.2.1 Display shifting

Display down scale shifting

Display full scale shifting

M

(accessible according to the programmed 

access code)

ADJ

ADJ

After injecting an input signal corresponding to the down (or full) display 

scale, press simultaneously on keys 

and      (or      and     ). The 

message 

(          ) will appear alternating with the value, to indi-

cate that you are in the menu adjustment.

Press       and       to decrease or increase the down (or full) display 

scale.

If you keep pressing during 3s. on key      or      you can access to a 

fast decreasing or increasing of the display value.

M

ADJ

ADJ

• 

Case of a temperature input

On a temperature input, if one of the two settings is performed, this will 

correspond to an offset, which means that all the points will be shifted by 

the same quantity.
On the contrary, if the two settings are performed, the slope and offset 

will be corrected in order to obtain the required result.

example

For a PT100 input at 0°C, the obtained display will be -000.3

For 500°C the display will be 0500.2. To correct this display, the display 

down scale must be shifted by 3 points to obtain 000.0 and the display 

full scale by -2 points to obtain 0500.0.

Press      to validate the shifing. The message 

   appears during 

the acknowledgement of the shifting (1s.), then the instrument reverts to 

mode measure. Once the shiftings are validated, the input thus shifted 

will keep this shifting event after a setting off tension. 

Press       (or do not press any key during 20 s.) to revert to the measu-

re display without modifications. 

• 

Case of a process, resistance or potentiometer input

The instrument will then re-adjust its scale factor and its display factor to 

obtain the required result on the display.

M

OK

note

:  only for 

temperature inputs

From the menu READ, the performed scale shiftings can be visualised in 

the submenu INP:

OFFS

000.3

offset     

shifting

= shifting by 

1 point with 

       or

dDIS

slope and 

offset

shifting

= shifting by 

2 points  

with 

  and

display down scale 

shifting

display down scale

display full scale 

shifting

display full scale

ADJ

F.DIS

500.2

ADJ

-000.2

-000.3

000.3

ADJ

ADJ

ADJ

ADJ

Suppressing of the input shifting : 

(Case of a temperature input only)

The menu ADJ in the mode programming of a temperature input allows 

suppressing or not suppressing the entered shifting.

NO : 

the instrument will revert to the factory settings

Yes :

 the instrument will take the performed (offset and/or slope)   

         adjustments into account.

Содержание TPI-SI 40 Series

Страница 1: ...rindas Parc d activit d Arbora N 2 69510 Soucieu en Jarrest T l 04 72 31 31 30 Fax 04 72 31 31 31 Tel Intern 33 4 72 31 31 30 Fax Intern 33 4 72 31 31 31 http www ardetem com e mail info ardetem com U...

Страница 2: ...gramming of a new access code with the p19 console 4 11 Functions accessible from the main menu p20 4 11 1 Simulation of the display p20 4 11 2 Simulation of the analog outputs p20 4 11 3 Deleting of...

Страница 3: ...e information vertically or horizon tally according to the sense in which the converter is mounted Series TPI SI 40 440 Process inputs in standard version One bidirectionnal DC current or voltage inpu...

Страница 4: ...on with graphical rear lit LCD The LCD allows visualising 4 pieces of information the value of the measure 5 mm high the unit of the displayed measure the value of the analog output or the name of the...

Страница 5: ...s 0 440 and 0 2 2 k 0 8 8 k optional Potentiometer Supply for 2 wire sensor 200 850 60 260 76 500 On input mV V mA Resistive sensors and potentiometer 328 1562 200 270 from 100 to 10 k 328 518 0 1 C 0...

Страница 6: ...wer supply 2 CONNECTINGS Wiring In order to keep the safety the connection must be followed strict ly especially the setting to the earth of terminal A2 of the group supply Self extinguishing case of...

Страница 7: ...ogramming of the access code see p19 Display simulation see p20 Authorized by access code analog relay output analog output relay output PCOD SIMU Teleloading of a program ming file see p21 LOAD Exit...

Страница 8: ...ith or p13 without saving the configuration voltage input voltage input only choice of the caliber Special linearisation only current input to t sensors resistive sensors down scale 22 00 x 22 00 mA 1...

Страница 9: ...inearisation CJ E CJ T CJC YES NO ADJ To TC DISP TC L TC J TC K TCW5 TCW3 TC W TC N TC B TC E TC T TC R TC S oF oC CAL RES POT 10 0C CJC 60 0C 14 0F CJC 140 F 2 2 c Resistive sensors dINP 400 8888 FUN...

Страница 10: ...ove M Downwards move decrease Menu exit access Fast version only 4 4 2 Programming of the console display inputs process resistance potentiometer position of the decimal point DISP rES dDIS 88 88 F DI...

Страница 11: ...yed measure is 10 0 and 20 mA for a displayed measure of 100 0 In mode transmitter only the parameters are available For a mA input with dINP 0 00 and FINP 20 00 mA if dOU1 4 mA and F OU1 20 mA the va...

Страница 12: ...Safety features p17 Safeties option 2 relays if input mV or t option analog output if return value programmed REL1 LO HI OFF OUT I state of relay 1 in case of sensor rupture LO HI OFF state of relay...

Страница 13: ...YES NO REP1 value of output 1 in case of sensor rupture 00 00 rEP1 22 00 mA OFF ON 88 88 if return value OU2 I OU2 U or YES NO REP2 value of output 2 in case of sensor rupture 00 00 rEP2 22 00 mA 88 8...

Страница 14: ...as well as the alarm recordings After SAVE YES la console will show WAIT during the converter re initialisation phase 4 5 1 Mode transmitter indicator According to the choice SCALE YES NO you can cho...

Страница 15: ...and divide by 10 all the dis play related parameters In this example after modifying the parameter POIN from to F DIS will have to be modified from 3000 to 0300 and SP1 1 from 0300 to 0030 to obtain...

Страница 16: ...00 01 04 02 85 05 04 07 47 10 00 12 54 14 96 17 17 18 98 20 00 That is to say a curve of 10 equally long segments Measure range number of segments 20mA 10 2mA length of the segment For 10 segments nb...

Страница 17: ...mode Mode setpoint OFF ON setpoint Legend ON coil supplied OFF coil not supplied or MODx setpoint OFF ON SPX SPX TPI SI 41 N and AN Mode window Mode setpoint Mode window Choice of the state of the rel...

Страница 18: ...entering the correct access code or by pressing simultaneously and if the access to a quick entering has been authorized on the programming of the code see p19 4 7 4 Safeties Self diagnosis The conver...

Страница 19: ...7 8 9 10 400 600 1 0s 1 4s 2 0s 3 0s 5 0s 7 5s 10s 15s BRGT 1 1 1 1 4444 Setting of the digits brightness Lowest brightness Strongest brightness LdIG Inhibition of the last digit low weight In mode p...

Страница 20: ...nstrument check sum of the programme no 4 9 Access code An access code adjustable from 0000 to 9999 serves to protect the converter and its setpoints from unauthorized programming and to lock the acce...

Страница 21: ...analog output current output Entering of a new display value GENE GENE Value of the output if Enter the value to be injected M Press Menu to revert to measure dis play Note The instrument will carry o...

Страница 22: ...display The file stored in the console can be read by validating choice READ CONS In this case the reading organigramme of the file programming is the same as for the programming of the instrument se...

Страница 23: ...or 500 C the display will be 0500 2 To correct this display the display down scale must be shifted by 3 points to obtain 000 0 and the display full scale by 2 points to obtain 0500 0 Press to validate...

Страница 24: ...ed simply press and the converter will revert to mode measure taking the new values into account If no key is pressed after 60 s the converter will revert to the measure display without modification o...

Страница 25: ...enu Input type Voltage input Current input Temperature input Potentiometer input Resistance input Potentiometer and resistance inputs Input down scale Input full scale Choice of the processing functio...

Страница 26: ...esis in display points Time delay on relay X OFF MODx _ _I I_ _ AL x REL x ON REL SPx 1 SPx 2 HYSx TIM x SPx _I I_ I_ _I SCAL POIN dDIS FDIS Yxx CUT 10 FILT UNIT T MES RES 0 10 Display parameters Subm...

Страница 27: ...upture safety Validation or not of the sensor rupture Sensor rupture inactive Sensor rupt active State of relay X in case of sensor rupture No sensor rupture associated with the relay Relay de activat...

Страница 28: ...ress 200 202 204 208 210 212 290 291 Value of the analog output n 1 on TPI SI 440 441 in A mA output Minimum value of the displayed value Maximum value of the displayed value Direct measure Value of t...

Страница 29: ...3 Nbr of MSB words LSB 2 bytes 2 bytes Slave number 1 byte 1 byte 1 byte Function 3 or 4 2 bytes CRC 16 Number of read bytes Response pattern 1st word MSB value LSB 2 bytes 2nd word MSB value LSB 2 by...

Страница 30: ...byte 1 x 256 byte 2 0 x 2563 0 x 2562 19 x 256 136 5000 Reading of the address 120 decimal point 2 displayed measure 50 00 9 4 CRC 16 calculation algorythm FFFF CRC CRC BYTE CRC END yes no n 0 n n 1 y...

Страница 31: ...s The directive EMC 2014 30 UE generic standards IEC 61000 6 2 Immunity for industrial environments IEC 61000 6 4 Rejections for industrial environments The directive ATEX 2014 34 UE standards EN 6007...

Страница 32: ...p31...

Отзывы: