B-3
INSTALLATION
B-3
PARAMETERS PRESETTING RANGES
SYMBOLS
ON UI
MMA
DC TIG
DC TIG
/PULSE
AC TIG
AC TIG
/PULSE
AC TIG
/MIX
SPOT
Preflow Time
( S )
/
0
~
10
Initial Current
( A )
I
s
/
10~200
/
Slope Up Time
( S )
T
UP
/
0
~
10
0
~
10
0
~
10
0
~
10
0
~
10
/
Welding
Current ( A )
I
1
10~170
10~200
Base Current
( % of I
1
)
I
2
/
/
10~90
/
10~90
/
/
Slop Down
Time ( S )
T
DOWN
/
0
~
10
/
Crater Current
( A )
I
E
/
10~200
/
Postflow Time
( S )
/
0
~
30
PULSE
FREQUENCY
( Hz )
/
/
/
0.1~800
/
0.1~800
/
/
PULSE RATIO
( % )
/
/
/
10~90
/
10~90
/
/
AC
FREQUENCY
( Hz )
/
/
/
/
30~200 ( I
1
≤100 )
30~100 ( I
1
>100 )
/
AC BALANCE
( % )
/
/
/
/
10~50
10~50
10~50
/
Spot Time
( S )
T
UP
/
/
/
/
/
/
0.01-5
Hot Start
Current ( A )
I
s
10~200
/
/
/
/
/
/
Arc Force
Current ( A )
T
UP
10~200
/
/
/
/
/
/
Note: The above parameters are subject to change with the improvement of machines.