F-3
MAINTANANCE AND TROUBLESHOOTING
F-3
Troubleshooting Guide
No.
Problem
Possible Cause
What to do
1
Yellow Thermal
Indicator is on
Input voltage is too high
(≥15%)
Switch off power source; Check the main supply.
Restart welder when power recovers to normal
state.
Input voltage is too low
(≤15%)
Insufficient ventilation.
Improve the ventilation.
Ambient temperature is too
high.
It
will
automatically
recover
when
the
temperature reduces.
Exceeding the rated
duty-cycle.
It
will
automatically
recover
when
the
temperature reduces.
2
Wire feeding motor
not working
Potentiometer faulty
Change potentiometer
Contact tip is blocked.
Change contact tip
Drive roll is loose.
Increase tension on drive roll
3
Cooling Fan not
working or turning
very slowly
Switch broken
Replace the switch
Fan broken
Replace or repair the fan
Wire broken or disconnected Check the connection
4
Arc is not stable and
spatter is large
Too large contact tip makes
the current unsteady
Change to proper contact tip and / or drive roll.
Too thin power cable makes
the power unstable.
Change the power cable .
Too low input voltage
Correct the input voltage.
Wire feeding resistance is
too large
Clean or replace the liner and keep the gun
cable straight.
5
Arc will not start
Work cable broken
Connect / repair work cable
Work piece has greasy, dirty,
rusty or painted
Clean work piece, ensure good electrical contact
between work clamp and job.
6
No shielding gas
Torch is not connected
properly.
Re-connect the torch .
Gas pipe is crimped or
blocked.
Check gas system.
Gas hose broken.
Repair or replace
7
Others
Please contact our Field Service Shop.
Содержание 210C MIG