Arctiko ULUF P390 Скачать руководство пользователя страница 12

23

22

Outcome frames

The outcome frames will be accompanied by a long beep.

Warnings

To accept a warning, press “       ”.

DOOR OPEN

Содержание ULUF P390

Страница 1: ...ORIGINAL OPERATING INSTRUCTIONS Integraline RANGE ULUF P390 P500 P610 P820...

Страница 2: ...vents Compressor failure alarm Outcome frames Contents Page 4 4 4 4 5 5 5 6 6 6 6 7 7 8 8 9 10 11 12 13 15 15 16 16 17 17 18 18 18 19 20 21 22 Warnings How to turn on the device Menu user How to chang...

Страница 3: ...ctiko is obligated as a supplier to ensure the users safety when operating one of our appliances To prevent personal and material injury or damage please follow the instructions in this manual Intende...

Страница 4: ...Be careful not to tip over the appliance during transport to prevent damage or injury Plastic bags pose a suffocation risk Keep away from children Inactivity for extended period If the appliance must...

Страница 5: ...n or der to achieve optimal operating results Firm and levelled floor Placing the appliance on a firm and flat floor reduces the risk of excessive noise and vibration Away from any heat sources Avoid...

Страница 6: ...connection is a 3 prong connection use a three pin plug and connect the conductor with yellow green insulation to ground In order to maintain a stable operation of the unit voltage variation cannot d...

Страница 7: ...filter less construc tion for less maintenance low noise level low energy consumption low heat dissipation and excellent temperature stability The compressors and cooling system is located in the top...

Страница 8: ...r openings and control the lights 15 Cover for noise reduction and air flow management 5 Probe See Probes and portholes 16 Remote alarm connection For connecton of additional alarm equipment 6 Door ha...

Страница 9: ...ve keyboard You can access a variation of settings in order to adjust your unit for your exact needs A 4GB microSD is provided as standard installed internally for recording functional data every 30 s...

Страница 10: ...19 18 Info events Door Warning Action Icons Temperature alarms...

Страница 11: ...oller The other compressor will keep running To reset the alarm and reenable the compressor accept the alarm and turn the unit off and on again During pulldown this alarm may be activated If this happ...

Страница 12: ...23 22 Outcome frames The outcome frames will be accompanied by a long beep Warnings To accept a warning press DOOR OPEN...

Страница 13: ...press Enter Menu user STAND BY SETPOINT LIMITS ACCESS LIST ECOMODE EVENTS GRAPHICS DEFROST SETTINGS SERVICE press and hold to turn off the controller change the temperature setpoint set the high low...

Страница 14: ...27 26 How to change the setpoint How to change the alarm limits Press the Menu key to access the menu...

Страница 15: ...29 28 Access list Ecomode setting KEY FUNCTION...

Страница 16: ...30 Event list If the event list is empty the icon above will be shown Shows number of pages with events Press or to change page Graphs SCROLLING THE FRAPH AND ENABLING THE TRACES REPRESENTATION CRITER...

Страница 17: ...edit the telephone numbers where to send the alert messages set the language of user interface edit machine name by alphanumeric keyboard How to set date hour Press select to move the highlight and t...

Страница 18: ...is 111 Service For accessing the service menu The service settings are reserved for qualified Arctiko service personnel By entering the admin password both the admin and user passwords can be changed...

Страница 19: ...Pressing the backup icon shows the usb pen insertion request frame with 20 second time out If the usb pen has been recognised the setting page of the months to download is displayed otherwise the disp...

Страница 20: ...stributor 2 To convert the data open the program Thermo Converter To convert the file press the DAT TO CSV CONVERT button 1 Insert the USB drive with the loaded data in a computer 3 Open the file by f...

Страница 21: ...ght corner of the compressor department 1 Logo 2 Contact information 3 Model 4 Voltage range 5 Refrigerant and quantity 6 WEEE Waste from Electrical and Electronic Equipment 7 Compressor type 8 CE mar...

Страница 22: ...operation 1h RELAIS U2 U2 Relay status COMP 24h Compressor operation 24h RELAIS U3 U3 Relay status COMP ON Time on compressor RELAIS U4 U4 Relay status COMP OFF Time o compressor RELAIS U5 U5 Relay st...

Страница 23: ...ssor compartment using only a dry brush or a vacuum cleaner Parts in the refrigeration system for this appliance are completely sealed These do not require any lubrication If you would like more infor...

Страница 24: ...unit away from the sunlight or heat source Frequent door openings may cause the temperature to rise Check if there has been frequent door openings Leave the door closed until the temperature in the un...

Страница 25: ...5080063 02 GB Arctiko A S Oddesundcej 39 DK 6715 Esbjerg N Phone 45 7020 0328 info arctiko com arctiko com...

Отзывы: