Failure events
NOTIFICATION OF PREVIOUS ALARM
To accept a failure, press the center of the screen.
Compressor Failure Alarm
The controller is equipped with a compressor failure detection feature.
If the controller detect an unusual temperature profile on one of the
compressors it will disable that compressor and activate an alert on the
controller. The other compressor will keep running.
To reset the alarm and reenable the compressor; accept the alarm and turn
the unit off and on again. During pulldown this alarm may be activated. If this
happens please reset the alarm. If the alarm keeps reoccuring please contact
your distributor or Arctiko service for help.
1
2
19.
8
cooling
COMPRESSOR FAULT
HIGH TEMP. AFTER BLACKOUT
LOGIC FAILURE
COMPRESSOR FAULT
k1
1 <-> 2
19.8 c
0 m
k1
To accept a failure, press the center of the screen.
COMPRESSOR FAILURE ALARM
OCCURED
COMPRESSOR FAILURE ALARM
UNRESOLVED