1.  Ice will form on the sub lids in the freezer. This ice should be removed with a scraper at regular 

intervals. (Remember safety gloves).

2.  Ice on the inside of the box should be removed as required, as it reduces the cooling capacity!

Take the contents out of the freezer. Pull out the plug and leave the lid open until the ice can be 

removed. (Remember safety gloves).

3.  Dry the inner container with a cloth until it is not damp any longer!
4.  Clean the outside of the freezer with a damp cloth. Be careful not to get damp (water) on the

electrical parts or water into the vent holes, as water and damp may damage the electrical
parts and cause the freezer to short-circuit!

5.  The ice formed on the inside of the lid should be removed with a wooden/plastic scraper. This ice will 

build up because of the low temperatures inside the box, and if it is not removed it will

cause the lid to open.

6.  Use authorised cleaning products. The use of alcohol, dissolvents and alkaline cleaning agents

is prohibited.

7.  Clean the vent holes on the rear condenser with a vacuum cleaner at least once a year 

(see the sketches).

Do not put bottles containing carbonic acid or inflammable products in the freezer.

WARNING

Before carrying out maintenance, unplug the appliance.
Do not use abrasive products; stain removers (e.g. acetone, trichloroethylene) to clean the appliance.

Spare parts

When ordering spare parts that you can easily fit yourself, please give unit type number and the function of 
the part(s) concerned.
 

Disposal of the freezer

To prevent harmful environmental effects, contact the distributor and ask where the freezer should be 
delivered.

Remove the locking function so that children cannot be locked in the freezer whilst playing.

You can obtain information on the disposal of refrigeration appliances from:

Your supplier

Authorities (The Local council, Ministry of the Environment, etc.)

17

Содержание SUF 100

Страница 1: ...OPERATING INSTRUCTIONS SUF MODELS...

Страница 2: ...5 Control panel 6 Main functions 7 How to lock the keyboard 8 Parameters 9 Alarms 10 Alarm relay management 10 Digital input 10 Start defrost 12 Alarm recovery 12 Connections 13 Default setting value...

Страница 3: ...s WARNING Keep ventilation openings that are placed in the appliance enclosure or in the built in structure clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the...

Страница 4: ...re is too high there is a risk that the freezer will not operate correctly It is recommended that the room is ventilated so that the room temperature does not exceed 77 F at most Class N 3 Place the f...

Страница 5: ...l parts it may cause short circuiting 6 In the event of functional or electrical irregularities please contact an authorised servicing engineer Before commissioning Clean the freezer both inside and o...

Страница 6: ...emperature display USE OF LEDS Each LED function is described in the following table 1 Press and release the key 2 The Lo message will be displayed followed by the minimum temperature recorded 3 By pr...

Страница 7: ...EFROST Push the DEF key for more than 2 seconds and a manual defrost will start HOW TO CHANGE A PARAMETER VALUE To change the parameter s value operate as follows 1 Enter the Programming mode by press...

Страница 8: ...sage will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX o Min temperature stored 3 If a key is pressed more than 3s the POF messag...

Страница 9: ...n Compressor ON time with faulty probe 0 255 min time during which the compressor is active in case of faulty thermostat probe With COn 0 compressor is always OFF COF Compressor OFF time with faulty p...

Страница 10: ...r failure y the alarm relay is activated if a temperature alarm happens during a power failure n the alarm relay is never activated during a power failure ALF Alarm relay activation for all the alarms...

Страница 11: ...1F parameter DOOR SWITCH INPUT i1F dor It signals the door status and the corresponding relay output status through the odc parameter no Fan normal any change CPr F_C Compressor OFF Since the door is...

Страница 12: ...unction is enabled until the digital input is activated DIGITAL INPUTS POLARITY The digital input polarity depends on the i1P parameter i1P CL the input is activated by closing the contact i1P OP the...

Страница 13: ...13 CONNECTIONS XR30CX 20A COMPRESSOR 12Vac dc supply connect to the terminals 7 and 8 24Vac dc supply connect to the terminals 7 and 8 120Vac supply connect to the terminals 7 and 8...

Страница 14: ...14 82 82 95 60 DEFAULT SETTING VALUES...

Страница 15: ...te to 02 mbar Evacuation must be performed at two places in the system both from the filling pipe and from the pipe mounted on the pressure side of the compressor Mount the capillary pipe with mountin...

Страница 16: ...oose fold which is up is cut off Beware not to damage the rest of the gasket 3 The new gasket with the removed fold is placed on the lid 4 The upper part of the gasket is twisted outwards and the scre...

Страница 17: ...side the box and if it is not removed it will cause the lid to open 6 Use authorised cleaning products The use of alcohol dissolvents and alkaline cleaning agents is prohibited 7 Clean the vent holes...

Страница 18: ...18 for SUF 100 External alarm Earth connection in compressor compartment External alarm Sensor Battery 6V Sensor Battery Terminal blocks...

Страница 19: ...19 for SUF 500 External alarm Earth connection in compressor compartment External alarm Sensor Battery 6V Terminal blocks Sensor Battery Starting relay...

Страница 20: ...LAMMEFJORDSVEJ 5 DK 6715 ESBJERG N DENMARK TEL 45 70 20 03 28 FAX 45 70 20 03 29 5080100 04 GB WWW ARCTIKO INT COM WWW ARCTIKO INT COM...

Отзывы: