3.0 Inspection, Maintenance and Storage

3.1 Record Keeping

All components should be checked daily when used regularly. Regardless of the usage, each

respirator system requires a documented inspection and replacement program. A trained and 

competent person with full knowledge of respiratory equipment should carry this out. Records

should be maintained throughout the life of the equipment. Regulatory Guidance can be found

in the following documents: OSHA 29CFR 1910 Part 134 and ANSI Z88.2. 
Use only 

A

RC

O

NE

®

A

IR

P

LUS

®

PAPR

components and replacement parts manufactured by 

A

RC

O

NE

®

and approved by NIOSH for use with the respirator system. Inspect all components of

the respirator system during cleaning, and before and after each use for signs of wear, tear or

damage that might reduce the degree of protection originally provided. Respirators used by

more than one person must be cleaned, inspected, and sanitized after each use. If not cleaned,

contamination may cause illness or disease. Allow components to air dry before reassembling. 

3.2 Cleaning 

1. ALWAYS INSPECT your 

A

RC

O

NE

®

A

IR

P

LUS

®

PAPR

system before each use and after

cleaning. Clean the external surfaces of the PAPR system with a soft cloth dampened in a

mild solution of clean water and mild detergent. Never use abrasive cleaners. During

cleaning, ensure that NO water is allowed to enter into the blower unit or battery pack as this

could damage the blower or battery internal parts. Never immerse the unit in liquid.

2. Detach the Breathing Tube from the Blower unit and the Headtop (Section 4.4), and wipe

the connection sites.

3. Detach the Face Seal from the Headtop before cleaning (Section 4.5). Hand wash in a mild

solution of clean water and mild detergent. Air dry the Face Seal then re-apply a fire retardant

spray (Fig. 16) and allow the Face Seal to air dry before reattaching to the Headtop.

4. Allow all components to dry away from direct heat.

5. Refer to the 

A

RC

O

NE

®

Auto-Darkening Filters manual for maintenance of applicable

components.

®

-15-

Figure 16

Содержание AIRPLUS

Страница 1: ...USER INSTRUCTION MANUAL 85 Independence Drive Taunton MA 02780 TEL 508 884 9600 TOLL FREE 800 223 4685 FAX 508 884 9666 AP01 UI Rev E Powered Air Purifying Respirator ...

Страница 2: ...xposure which may lead to serious bodily injury or loss of life Use by unqualified or untrained persons or use other than in accordance with this instruction manual is dangerous and could expose user to serious bodily injury or loss of life Do not make any modifications to any part of this system other than those specified in this manual Do not use any replacement parts other than those specified ...

Страница 3: ...ops 2 7 Waist Belt 2 8 Pre Operational Inspection 2 9 Wearing Donning PAPR 2 10 Removing Doffing PAPR 2 11 Troubleshooting 3 0 Inspection Maintenance and Storage 3 1 Record Keeping 3 2 Cleaning 3 3 Inspection 3 4 Storage 4 0 Replacement 4 1 Battery 4 2 Filter 4 3 Blower 4 4 Breathing Tube 4 5 Face Seal 4 6 Waist Belt 4 7 Special Instructions 5 0 Customer Information 5 1 Replacement Parts and Access...

Страница 4: ... Helmet Headtop with Face Seal A Choice of Auto Darkening Welding Filters One 1 HE Particulate Filter Blower Unit 7 4V Lithium Ion Battery and Charger Breathing Tube with Flame Retardant Cover Adjustable Waist Belt Airflow Indicator not shown Carrying Case not shown 3 ...

Страница 5: ...y remain safe in your work environment for a longer period of time and is of particular benefit where working conditions are hot or humid The ARCONE AIRPLUS Lithium Ion battery provides power for two 2 eight 8 hour shifts when the blower is set on low fan and one 1 eight 8 hour shift when the blower is set on high fan This rechargeable battery is encased in durable lightweight plastic and attaches...

Страница 6: ... Immediately replace worn or damaged components with ARCONE AIRPLUS PAPR components approved by NIOSH for use with this PAPR system 6 DO NOT use the ARCONE AIRPLUS PAPR system in inadequately ventilated areas where oxygen is less than 19 5 or in confined spaces such as tanks small rooms tunnels or vessels unless the confined space is well ventilated and contaminant concentrations are below the recom...

Страница 7: ...ation for Safe Use Before using the ARCONE AIRPLUS PAPR system you should ensure that all conditions for safe use have been satisfied Refer to Section 1 3 and Approval Labels enclosed 2 2 Battery The Lithium Ion battery included with your system does not need to be manually discharged Charge Recharge Battery 1 Turn off the blower if the battery is connected to the blower Note the battery may be eit...

Страница 8: ...e maintained see Section 2 5 Airflow Test THIS FILTER IS NOT MEANT TO BE REUSED DO NOT CLEAN AND REUSE THE FILTER SHOULD NEVER BE USED FOR PROTECTION AGAINST GASES OR VAPORS REFER TO SPECIFIC NIOSH FILTER APPROVAL LABELS FOR SPECIFIC INFORMATION ON USAGE AND LIMITATIONS PDF cr eat ed wi t h pdf Fact or y t r i alver si on www pdffactory com BLOWER BATTERY BATTERY EDGES LINE UP BOTH SIDES BLOWER ED...

Страница 9: ... blower unit on or off High Speed Fan increase airflow indicated by GREEN LED panel above power button Low Speed Fan decrease airflow indicated by GREEN LED panel above power button Filter Airflow status indicated with GREEN LEDs Filter Airflow status GOOD Filter Airflow status Near Full Battery When blower is turned on the LEDs will flash RED ALWAYS begin each shift with a fully charged battery A...

Страница 10: ...nd Airflow Indicator vertically 5 The airflow is sufficient only if the indicator ball reaches the minimum flow rate level Fig 9 6 If the Airflow Indicator ball sits below the minimum flow rate level it is necessary to charge the battery or change the filter Sections 2 2 2 3 2 6 Headtop 2 6 1 Vision Welding Helmet 1 Install and lock the breathing tube into the airduct on the Headtop Fig 10 2 Don t...

Страница 11: ...ore air flow at the top of the airduct Fig 13a and 13b b A closed valve allows more air flow at the sides of the airduct Fig 14a and 14b 3 Don the Headtop over your face Adjust the headgear rachet wheel by pushing in and turning until a satisfactory tightness is achieved 4 Adjust the Face Seal fit with the pull cord by pressing on the lock and adjusting the cord length until a tight fit is achieve...

Страница 12: ...C B A A Figure 13a Figure 13b Figure 14a Figure 14b Eagle Internal Flow Direction Regulation 11 ...

Страница 13: ... and the filter cover is secured 6 Breathing Tube is connected and secured to the Blower unit 7 Breathing Tube is connected and secured to the Headtop 8 Face Seal is installed and secured to the Headtop 9 Face Seal and helmet are free of holes rips cuts and tears 10 Face Seal is clean and free of contaminants 11 Blower is operational and once turned on check that a The Battery status is above rech...

Страница 14: ...op 3 Remove Headtop 4 Unclip Waist Belt and remove from waist OSHA 1910 134 does not require fit testing for loose fitting face pieces however excessive facial hair may cause an incomplete seal When in doubt remove excessive facial hair where it interferes with the seal between the users face and the face seal Failure to properly connect the Breathing Tube to the Headtop Assembly and confirm airfl...

Страница 15: ... blower connection battery is snapped in place Blower does not turn on Battery not installed Install battery Battery not charged Recharge battery Defective switch Contact ARCONE Technical Support 800 223 4685 Motor defective Contact ARCONE Technical Support 800 223 4685 Battery fails to charge Check outlet voltage Connect to good 110 Volt outlet Defective charger Contact ARCONE Technical Support 8...

Страница 16: ...tized after each use If not cleaned contamination may cause illness or disease Allow components to air dry before reassembling 3 2 Cleaning 1 ALWAYS INSPECT your ARCONE AIRPLUS PAPR system before each use and after cleaning Clean the external surfaces of the PAPR system with a soft cloth dampened in a mild solution of clean water and mild detergent Never use abrasive cleaners During cleaning ensur...

Страница 17: ... prevent contaminants from entering into the ARCONE AIRPLUS PAPR system could lead to contaminant exposure resulting in serious bodily injury or loss of life Consult your local safety professional in event contaminant entry into the breathing tube or blower unit is suspected 16 Do not clean the HE filter by any means including forced air Doing so will damage the filter and void the Blower Unit war...

Страница 18: ...nd battery charger are not user serviceable Maintenance or replacement of parts should only be performed by ARCONE who has the necessary test equipment to ensure that all repairs are completed safely and recertified 17 Pull Away from Blower 2 Blower Battery Figure 17 DO NOT store respirator system in your work area or leave it unattended in a contaminated environment Respirable contaminants can re...

Страница 19: ...Retain pins in Eagle shell 3 Carefully pull the Face Seal away from the Headtop Installation 1 Align the Face Seal with the holes surrounding the Headtop Fig 19a and 19b 2 Be sure to place the pull string on the bottom of the Headtop Fig 20 3a Vision Use the screwdriver to screw in the screws and nuts through the helmet shell and corresponding Face Seal hole 3b Eagle Push the pins through the helm...

Страница 20: ...wer Installation 1 Thread the Waist Belt Strap through the side slots on the Blower Fig 22 2 Thread the Waist Belt Strap through the belt loops Fig 23 3 Thread the Waist Belt strap through the Clip and pull tight to secure the Blower to the Waist Belt Fig 24 19 Figure 23 Belt Loops Figure 22 Figure 24 Clip ...

Страница 21: ...figured from approved components as referenced on the NIOSH Approval Label for the applicable systems Powered Air Purifying Respirator Replacement Parts Part No Description AP1 15XX US Vision facepiece includes face seal and headgear airduct assembly XX color paint option as follows 00 Black 23 Speedway 26 Red Rock 33 Dragon Fire 43 Dream Weaver 55 Tank 68 Easy Rider AP1 02XX Eagle facepiece inclu...

Страница 22: ...pe Lithium Ion Voltage 7 4 V Current Hours 8400 mAh Operating Time Fully charged battery sixteen 16 hours at minimum speed eight 8 hours at maximum speed Charging Time 5 7 hours Charging Cycles 600 under ideal conditions may vary due to use or storage conditions Housing Impact proof ABS Weight 82 lb 0 37 kg Dimensions 5 9 in x 2 9 in x 1 65 in 150 mm x 74 mm x 42 mm Color Black Charger Type DC Rec...

Страница 23: ... replacements please proceed as follows PLEASE DO NOT CONTACT THE DISTRIBUTOR OR RETAILER FROM WHOM YOU PURCHASED THE RESPIRATOR 1 Contact ARCONE Technical Service 800 223 4685 for a Return Goods Authorization Number RGA 2 Send the complete respirator freight prepaid in a box with packaging material to protect the product from damage directly to ARCONE Technical Service 85 Independence Drive Taunt...

Страница 24: ...IS A DIVISION OF A C E INTERNATIONAL COMPANY 85 Independence Drive Taunton MA 02780 TEL 508 884 9600 TOLL FREE 800 223 4685 FAX 508 884 9666 Please visit our website and register product at www arc1weldsafe com ...

Отзывы: