Additionally: 

DO NOT WEAR THIS RESPIRATOR IF ANY OF THESE CONDITIONS EXIST:

-You CANNOT escape without the aid of the respirator. 

-Work area is inadequately ventilated. 

-Unknown contaminants are present. 

This 

A

RC

O

NE

® 

A

IR

P

LUS

®

PAPR

system is only part of an overall OSHA Respirator Program,

which contains the following documentation:
1. Administration

2. Use of Respirators

3. Selection of Respirators

4. Employee Training, Instructions, and Discipline

5. Inspection, Cleaning, Storage, and Repair

6. Emergency Use Respirators

7. Program Evaluation

1.4 Helmet and Welding Filter Approvals and Limitations

The 

A

RC

O

NE

®

welding helmet Auto-Darkening Filters have been tested to:

• ANSI Z87.1. Limitations: See Auto-Darkening Filter User Instruction Manual.

2.0 System Use 

2.1 Preparation for Safe Use 

Before using the 

A

RC

O

NE

®

A

IR

P

LUS

®

PAPR

system you should ensure that all conditions for safe

use have been satisfied. Refer to Section 1.3 and Approval Labels (enclosed). 

2.2 Battery

The Lithium-Ion battery included with

your system does not need to be 

manually discharged.
Charge/Recharge Battery:
1. Turn off the blower if the battery is

connected to the blower. (Note: the 

battery may be either connected to 

or disconnected from the blower unit to

recharge.)
2. Connect the charger to the battery (Fig.1).
Indicators on charger as follows:

Solid Red LED - Charging

Solid Green LED - Charge Complete

Flashing Red LED - Fault (Section 2.11) 

PAPR

-6-

Risk of Explosion! Use only the AirPlus Charger to recharge your 

Battery. Do not charge battery in temperatures less than 32°F (0C) or

greater than 104F (40C).

PD F created w ith pdfFactory t

rial version 

www.pdffactory.com

Charger

Battery

Battery

Connector

Insert Charger Lead into

Battery Connector

Figure 1

Содержание AIRPLUS

Страница 1: ...USER INSTRUCTION MANUAL 85 Independence Drive Taunton MA 02780 TEL 508 884 9600 TOLL FREE 800 223 4685 FAX 508 884 9666 AP01 UI Rev E Powered Air Purifying Respirator ...

Страница 2: ...xposure which may lead to serious bodily injury or loss of life Use by unqualified or untrained persons or use other than in accordance with this instruction manual is dangerous and could expose user to serious bodily injury or loss of life Do not make any modifications to any part of this system other than those specified in this manual Do not use any replacement parts other than those specified ...

Страница 3: ...ops 2 7 Waist Belt 2 8 Pre Operational Inspection 2 9 Wearing Donning PAPR 2 10 Removing Doffing PAPR 2 11 Troubleshooting 3 0 Inspection Maintenance and Storage 3 1 Record Keeping 3 2 Cleaning 3 3 Inspection 3 4 Storage 4 0 Replacement 4 1 Battery 4 2 Filter 4 3 Blower 4 4 Breathing Tube 4 5 Face Seal 4 6 Waist Belt 4 7 Special Instructions 5 0 Customer Information 5 1 Replacement Parts and Access...

Страница 4: ... Helmet Headtop with Face Seal A Choice of Auto Darkening Welding Filters One 1 HE Particulate Filter Blower Unit 7 4V Lithium Ion Battery and Charger Breathing Tube with Flame Retardant Cover Adjustable Waist Belt Airflow Indicator not shown Carrying Case not shown 3 ...

Страница 5: ...y remain safe in your work environment for a longer period of time and is of particular benefit where working conditions are hot or humid The ARCONE AIRPLUS Lithium Ion battery provides power for two 2 eight 8 hour shifts when the blower is set on low fan and one 1 eight 8 hour shift when the blower is set on high fan This rechargeable battery is encased in durable lightweight plastic and attaches...

Страница 6: ... Immediately replace worn or damaged components with ARCONE AIRPLUS PAPR components approved by NIOSH for use with this PAPR system 6 DO NOT use the ARCONE AIRPLUS PAPR system in inadequately ventilated areas where oxygen is less than 19 5 or in confined spaces such as tanks small rooms tunnels or vessels unless the confined space is well ventilated and contaminant concentrations are below the recom...

Страница 7: ...ation for Safe Use Before using the ARCONE AIRPLUS PAPR system you should ensure that all conditions for safe use have been satisfied Refer to Section 1 3 and Approval Labels enclosed 2 2 Battery The Lithium Ion battery included with your system does not need to be manually discharged Charge Recharge Battery 1 Turn off the blower if the battery is connected to the blower Note the battery may be eit...

Страница 8: ...e maintained see Section 2 5 Airflow Test THIS FILTER IS NOT MEANT TO BE REUSED DO NOT CLEAN AND REUSE THE FILTER SHOULD NEVER BE USED FOR PROTECTION AGAINST GASES OR VAPORS REFER TO SPECIFIC NIOSH FILTER APPROVAL LABELS FOR SPECIFIC INFORMATION ON USAGE AND LIMITATIONS PDF cr eat ed wi t h pdf Fact or y t r i alver si on www pdffactory com BLOWER BATTERY BATTERY EDGES LINE UP BOTH SIDES BLOWER ED...

Страница 9: ... blower unit on or off High Speed Fan increase airflow indicated by GREEN LED panel above power button Low Speed Fan decrease airflow indicated by GREEN LED panel above power button Filter Airflow status indicated with GREEN LEDs Filter Airflow status GOOD Filter Airflow status Near Full Battery When blower is turned on the LEDs will flash RED ALWAYS begin each shift with a fully charged battery A...

Страница 10: ...nd Airflow Indicator vertically 5 The airflow is sufficient only if the indicator ball reaches the minimum flow rate level Fig 9 6 If the Airflow Indicator ball sits below the minimum flow rate level it is necessary to charge the battery or change the filter Sections 2 2 2 3 2 6 Headtop 2 6 1 Vision Welding Helmet 1 Install and lock the breathing tube into the airduct on the Headtop Fig 10 2 Don t...

Страница 11: ...ore air flow at the top of the airduct Fig 13a and 13b b A closed valve allows more air flow at the sides of the airduct Fig 14a and 14b 3 Don the Headtop over your face Adjust the headgear rachet wheel by pushing in and turning until a satisfactory tightness is achieved 4 Adjust the Face Seal fit with the pull cord by pressing on the lock and adjusting the cord length until a tight fit is achieve...

Страница 12: ...C B A A Figure 13a Figure 13b Figure 14a Figure 14b Eagle Internal Flow Direction Regulation 11 ...

Страница 13: ... and the filter cover is secured 6 Breathing Tube is connected and secured to the Blower unit 7 Breathing Tube is connected and secured to the Headtop 8 Face Seal is installed and secured to the Headtop 9 Face Seal and helmet are free of holes rips cuts and tears 10 Face Seal is clean and free of contaminants 11 Blower is operational and once turned on check that a The Battery status is above rech...

Страница 14: ...op 3 Remove Headtop 4 Unclip Waist Belt and remove from waist OSHA 1910 134 does not require fit testing for loose fitting face pieces however excessive facial hair may cause an incomplete seal When in doubt remove excessive facial hair where it interferes with the seal between the users face and the face seal Failure to properly connect the Breathing Tube to the Headtop Assembly and confirm airfl...

Страница 15: ... blower connection battery is snapped in place Blower does not turn on Battery not installed Install battery Battery not charged Recharge battery Defective switch Contact ARCONE Technical Support 800 223 4685 Motor defective Contact ARCONE Technical Support 800 223 4685 Battery fails to charge Check outlet voltage Connect to good 110 Volt outlet Defective charger Contact ARCONE Technical Support 8...

Страница 16: ...tized after each use If not cleaned contamination may cause illness or disease Allow components to air dry before reassembling 3 2 Cleaning 1 ALWAYS INSPECT your ARCONE AIRPLUS PAPR system before each use and after cleaning Clean the external surfaces of the PAPR system with a soft cloth dampened in a mild solution of clean water and mild detergent Never use abrasive cleaners During cleaning ensur...

Страница 17: ... prevent contaminants from entering into the ARCONE AIRPLUS PAPR system could lead to contaminant exposure resulting in serious bodily injury or loss of life Consult your local safety professional in event contaminant entry into the breathing tube or blower unit is suspected 16 Do not clean the HE filter by any means including forced air Doing so will damage the filter and void the Blower Unit war...

Страница 18: ...nd battery charger are not user serviceable Maintenance or replacement of parts should only be performed by ARCONE who has the necessary test equipment to ensure that all repairs are completed safely and recertified 17 Pull Away from Blower 2 Blower Battery Figure 17 DO NOT store respirator system in your work area or leave it unattended in a contaminated environment Respirable contaminants can re...

Страница 19: ...Retain pins in Eagle shell 3 Carefully pull the Face Seal away from the Headtop Installation 1 Align the Face Seal with the holes surrounding the Headtop Fig 19a and 19b 2 Be sure to place the pull string on the bottom of the Headtop Fig 20 3a Vision Use the screwdriver to screw in the screws and nuts through the helmet shell and corresponding Face Seal hole 3b Eagle Push the pins through the helm...

Страница 20: ...wer Installation 1 Thread the Waist Belt Strap through the side slots on the Blower Fig 22 2 Thread the Waist Belt Strap through the belt loops Fig 23 3 Thread the Waist Belt strap through the Clip and pull tight to secure the Blower to the Waist Belt Fig 24 19 Figure 23 Belt Loops Figure 22 Figure 24 Clip ...

Страница 21: ...figured from approved components as referenced on the NIOSH Approval Label for the applicable systems Powered Air Purifying Respirator Replacement Parts Part No Description AP1 15XX US Vision facepiece includes face seal and headgear airduct assembly XX color paint option as follows 00 Black 23 Speedway 26 Red Rock 33 Dragon Fire 43 Dream Weaver 55 Tank 68 Easy Rider AP1 02XX Eagle facepiece inclu...

Страница 22: ...pe Lithium Ion Voltage 7 4 V Current Hours 8400 mAh Operating Time Fully charged battery sixteen 16 hours at minimum speed eight 8 hours at maximum speed Charging Time 5 7 hours Charging Cycles 600 under ideal conditions may vary due to use or storage conditions Housing Impact proof ABS Weight 82 lb 0 37 kg Dimensions 5 9 in x 2 9 in x 1 65 in 150 mm x 74 mm x 42 mm Color Black Charger Type DC Rec...

Страница 23: ... replacements please proceed as follows PLEASE DO NOT CONTACT THE DISTRIBUTOR OR RETAILER FROM WHOM YOU PURCHASED THE RESPIRATOR 1 Contact ARCONE Technical Service 800 223 4685 for a Return Goods Authorization Number RGA 2 Send the complete respirator freight prepaid in a box with packaging material to protect the product from damage directly to ARCONE Technical Service 85 Independence Drive Taunt...

Страница 24: ...IS A DIVISION OF A C E INTERNATIONAL COMPANY 85 Independence Drive Taunton MA 02780 TEL 508 884 9600 TOLL FREE 800 223 4685 FAX 508 884 9666 Please visit our website and register product at www arc1weldsafe com ...

Отзывы: