background image

FAMB2 Half-Mask

Respirator System User Manual

www.bullard.com

 WARNING

Read all instructions and warnings before using this respirator. Save this 
manual for future use. Failure to follow these warnings could result in 
death or serious injury.

General Information

Bullard’s FAMB2 airline respirator, when properly used, provides a 
continuous flow of air from a remote air source to the respirator wearer. 
FAMB2 respirators offer protection from airborne contaminants that are 
not immediately dangerous to life or health (IDLH), or that do not exceed 
concentrations allowed by applicable OSHA, EPA, NIOSH or ACGIH regulations 
and recommendations for continuous-flow class airline half-mask respirators.
FAMB2 airline respirators are approved by NIOSH (TC-19C-xxx Type C, 
Continuous-Flow Class) to provide respiratory protection in general purpose 
applications, including spray painting, tank cleaning, chemical and pesticide 
handling, and other industrial or agricultural applications. The FAMB2 
respirator is NOT to be used in confined spaces or IDLH conditions.
FAMB2 respirators are compatible with breathing air sources such as 
breathing air compressors or Bullard Free-Air

®

 Pumps. Bullard offers the 

appropriate approved breathing tube assembly and air supply hose to connect 
the FAMB2 respirator to these breathing air sources.  
 FAMB2 facepieces are available in three sizes. 
The new FAMB2 masks feature the Bullard logo on the bridge of the nose and 
are designed with a headband assembly that has four points of attachment; 
two on each side of the face. The three sizes of replacement masks for this 
style are FAM2S (small), FAM2M (medium), and FAM2L (large). Fit test kit 
FAMAK is available for fit-testing the FAM2S, FAM2M and FAM2L masks.
 Contact Bullard or a local authorized distributor for more information about 
FAMB2 respirators.

Table of Contents

General Information .......................................................................................... 1
Component Concept ........................................................................................... 2
Mask/Fitting Assemblies ................................................................................... 2
Air Supply Options .............................................................................................. 2
Warnings ............................................................................................................ 3
Operations....................................................................................................... 4,5
Breathing Air Pressure Table ............................................................................. 5
FAMB2 Respriator Assembly
 

Donning ..................................................................................................... 6

 

Doffing ....................................................................................................... 6

Inspection, Cleaning and Storage ..................................................................... 7
Approval Label ................................................................................................... 8
Parts and Accessories .................................................................................. 9,10
Return Authorizations ...................................................................................... 10

Type C NIOSH Approval  

No. TC-19C-469 Continuous-Flow Class

Model FAM2M

Figure 1

Содержание FAM2M

Страница 1: ... used in confined spaces or IDLH conditions FAMB2 respirators are compatible with breathing air sources such as breathing air compressors or Bullard Free Air Pumps Bullard offers the appropriate approved breathing tube assembly and air supply hose to connect the FAMB2 respirator to these breathing air sources FAMB2 facepieces are available in three sizes The new FAMB2 masks feature the Bullard log...

Страница 2: ...r Supply Hose Options Connects breathing tube to air source supplying clean breathable air 2 Component Concept For use with breathing air compressors continuous flow For use with ambient air pumps continuous flow Model FAMB230 Model FAMB235 For use with breathing air compressors continuous flow For use with ambient air pumps continuous flow V10 3 8 I D Hose 4696 Starter Hose 545 Series Extension H...

Страница 3: ...tor Failure to use NIOSH approved components and replacement parts such as hoses and flow control devices voids NIOSH approval of the entire respirator invalidates all Bullard warranties and may cause death lung disease or exposure to other hazardous or life threatening conditions 7 Inspect all components of this respirator system daily for sign of wear tear or damage that might reduce the degree ...

Страница 4: ...o the respirator wearer See Figure 2 Supplied breathing air must AT LEAST meet the requirements forType 1 gaseous air described in the Compressed Gas Association Commodity Specifications F 7 1 Grade D or higher quality as specified by Federal Law 30 CFR Part II Subpart J 11 121 b The requirements for Grade D breathable air include Oxygen 19 5 23 5 Hydrocarbons condensed in mg m3 of gas 5 mg m3 max...

Страница 5: ... The breathing tube connection fitting MUST be secured to the belt that is supplied with this respirator Securing the air entry connection fitting helps prevent the air supply hose from snagging disconnecting or pulling the respirator off your face This table defines the air pressure ranges necessary to provide FAMB2 Series respirators with a volume of air that falls within the required range of 4...

Страница 6: ... your hand over the quick disconnect nipple located at the end of the breathing tube B Inhale until the mask collapses inward slightly indicating there is negative pressure Hold your breath for five seconds C The mask is deemed to be in proper position if it remained collapsed while the breath was being held and no inward leakage of outside air is detected D If mask doesn t collapse or if an inwar...

Страница 7: ...s of dirt or contaminants Rinse the respirator in clean warm water about 120 degrees F Shake to remove excess water and allow to air dry away from direct heat sunlight or contaminants Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided Be sure the quick disconnect fitting is screwed tightly int...

Страница 8: ... in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards D A ir line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G 7 1 Grade D or higher quality E Use only the pressure ranges and hose lengths specified in the User s Instructions J Failure to properly...

Страница 9: ...eries Starter Hose Kit Includes V1025ST hose with 1 4 Industrial Interchange quick disconnect coupler and V13 adaptor fitting 3 8 hose to 3 8 pipe 4696 25 ft Industrial Interchange starter hose kit V10 Series Extension Hose Kits Includes V11 hose to hose adaptor fitting and V13 hose to pipe fitting 3 8 hose to 3 8 pipe 5454 25 ft V1025EXT extension hose kit 5457 50 ft V1050EXT extension hose kit 5...

Страница 10: ... 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or shipping regulations prohibit the shipment of hazardous or contaminated materials Products suspected of contamination will be professionally discarded at the customer s expense 4 Ship returned products including those under warranty with all tran...

Страница 11: ...FAMB2 Half Mask Respirator System User Manual www bullard com ...

Страница 12: ...GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 www bullardextrem com Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 www bullard com 2010 Bullard All rights reserved Free Air is a registered trademark of Bullard 6081509159A 0710 ISO 9001 certified ...

Отзывы: