www.bullard.com

Component Concept

The FAMB2 airline respirator consists of three Bullard components: half-
mask, breathing tube assembly and air supply hose. All must be present and 
properly assembled to constitute a complete NIOSH-approved respirator (see 
Figure 2).
1. Half-mask with cradle headband and elastic straps
2. Breathing Tube Assembly
3. Air Supply Hose

 WARNING

Failure  to  use  complete  NIOSH  approved  Bullard  components  and 
replacement  parts  voids  approval  of  entire  assembly.    Basic  parts  are 
listed on the NIOSH Approval Label on Page 8.

Mask/Fitting Assemblies

Half-Mask Respirator with Breathing 

Tube Assembly:  

Comfortable silicone half-mask with breathing tube that 
connects the mask to air supply hose.

Air Supply Hose Options

Connects breathing tube to air source supplying clean 
breathable air.

2

Component Concept

For use with breathing air

compressors/continuous-flow

For use with ambient air

pumps/continuous flow

Model FAMB230

Model FAMB235

For use with breathing air

compressors/continuous-flow

For use with ambient air

pumps/continuous flow

V10 – 3/8" I.D. Hose

4696 Starter  Hose

545 Series Extension Hose

Extension hose available in 25, 50 

and 100 foot lengths with a variety 

of quick-disconnect fitting styles and 

materials. See parts list for details.

V20 – 1/2" I.D. Hose

V20 Starter/

Extension Hose

Available in 50 and 100 foot lengths 

with a variety of quick-disconnect 

fitting styles and materials. See 

parts list for details.

Figure 2

1.  Half-mask 

Facepiece

2.  Breathing 

Air Tube 

Assembly

3.  Air Supply 

Hose

Clean Breathable Air Source

Supplying Grade “D" or Higher 
Air Quality (See Breathing Air 
Requirements on page 5)

Содержание FAM2M

Страница 1: ... used in confined spaces or IDLH conditions FAMB2 respirators are compatible with breathing air sources such as breathing air compressors or Bullard Free Air Pumps Bullard offers the appropriate approved breathing tube assembly and air supply hose to connect the FAMB2 respirator to these breathing air sources FAMB2 facepieces are available in three sizes The new FAMB2 masks feature the Bullard log...

Страница 2: ...r Supply Hose Options Connects breathing tube to air source supplying clean breathable air 2 Component Concept For use with breathing air compressors continuous flow For use with ambient air pumps continuous flow Model FAMB230 Model FAMB235 For use with breathing air compressors continuous flow For use with ambient air pumps continuous flow V10 3 8 I D Hose 4696 Starter Hose 545 Series Extension H...

Страница 3: ...tor Failure to use NIOSH approved components and replacement parts such as hoses and flow control devices voids NIOSH approval of the entire respirator invalidates all Bullard warranties and may cause death lung disease or exposure to other hazardous or life threatening conditions 7 Inspect all components of this respirator system daily for sign of wear tear or damage that might reduce the degree ...

Страница 4: ...o the respirator wearer See Figure 2 Supplied breathing air must AT LEAST meet the requirements forType 1 gaseous air described in the Compressed Gas Association Commodity Specifications F 7 1 Grade D or higher quality as specified by Federal Law 30 CFR Part II Subpart J 11 121 b The requirements for Grade D breathable air include Oxygen 19 5 23 5 Hydrocarbons condensed in mg m3 of gas 5 mg m3 max...

Страница 5: ... The breathing tube connection fitting MUST be secured to the belt that is supplied with this respirator Securing the air entry connection fitting helps prevent the air supply hose from snagging disconnecting or pulling the respirator off your face This table defines the air pressure ranges necessary to provide FAMB2 Series respirators with a volume of air that falls within the required range of 4...

Страница 6: ... your hand over the quick disconnect nipple located at the end of the breathing tube B Inhale until the mask collapses inward slightly indicating there is negative pressure Hold your breath for five seconds C The mask is deemed to be in proper position if it remained collapsed while the breath was being held and no inward leakage of outside air is detected D If mask doesn t collapse or if an inwar...

Страница 7: ...s of dirt or contaminants Rinse the respirator in clean warm water about 120 degrees F Shake to remove excess water and allow to air dry away from direct heat sunlight or contaminants Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided Be sure the quick disconnect fitting is screwed tightly int...

Страница 8: ... in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards D A ir line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G 7 1 Grade D or higher quality E Use only the pressure ranges and hose lengths specified in the User s Instructions J Failure to properly...

Страница 9: ...eries Starter Hose Kit Includes V1025ST hose with 1 4 Industrial Interchange quick disconnect coupler and V13 adaptor fitting 3 8 hose to 3 8 pipe 4696 25 ft Industrial Interchange starter hose kit V10 Series Extension Hose Kits Includes V11 hose to hose adaptor fitting and V13 hose to pipe fitting 3 8 hose to 3 8 pipe 5454 25 ft V1025EXT extension hose kit 5457 50 ft V1050EXT extension hose kit 5...

Страница 10: ... 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or shipping regulations prohibit the shipment of hazardous or contaminated materials Products suspected of contamination will be professionally discarded at the customer s expense 4 Ship returned products including those under warranty with all tran...

Страница 11: ...FAMB2 Half Mask Respirator System User Manual www bullard com ...

Страница 12: ...GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 www bullardextrem com Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 www bullard com 2010 Bullard All rights reserved Free Air is a registered trademark of Bullard 6081509159A 0710 ISO 9001 certified ...

Отзывы: