![Architect 1600 SE Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/architect/1600-se/1600-se_professional-installers-consciousness-manual_2964178031.webp)
Architect
Model 1600 SE
Model 1601 SE
installer’s Guide
™
27
Appendix
The commands are broken into two groups:
Controls
and
In-
quiries
. The
Controls
issue instructions to the Model 1601 SE for
power control and channel muting; the
Inquires
return the status
of amplifier channels, AC line voltage, the amplifier temperature,
and the failure data log.
control commands
P0 (zero not ‘O’)
Main Power On
P1 Main Power Off
M1 Mute channel 1-2
M2 Mute channel 3-4
M3 Mute channel 5-6
M4 Mute channel 7-8
M5 Mute channel 9-10
M6 Mute channel 11-12
M7 Mute channel 13-14
M8 Mute channel 15-16
MA Mute all channels
U1 Unmute channel 1-2
U2 Unmute channel 3-4
U3 Unmute channel 5-6
U4 Unmute channel 7-8
U5 Unmute channel 9-10
U6 Unmute channel 11-12
U7 Unmute channel 13-14
U8 Unmute channel 15-16
UA Unmute all channels
inquiry commands
M? Binary string
showing all zones
mute status
0 = Mute
1 = Active (unmuted)
(i.e. ‘00100000’ –
zone 3 is unmuted)
S? Protection status
(zone 1-8 and
Amp)
T? Temperature
(zone 1-8)
P? Main power status –
0=off, 1=on
V? AC Line voltage –
Decimal numeric
value
L? Protection data log
(comma delimited
text, 10 lines)