appendix a
BrIDGInG THE arCHITECT
To increase the output power of the Architect, you can join
(bridge) two channels of the Architect into a single channel of 300
watts. Accomplishing this is a simple matter. Just press the Mono
button to send the same audio signal to both channels of the zone
and then connect the speaker terminals as shown in the diagram
below.
appendix B
USInG wITH ETHErnET-BaSED aUTomaTIon
SYSTEmS
The Ethernet LAN connection on the Model 1601 SE enables
remote control of the amplifiers power and channel muting. While
the internal web server of the Model 1601 SE provides an HTML
web page based interface, this is not the best means of control-
ling the unit from another computer system. The Architect Model
1601 SE provides a Telnet TCP/IP protocol for system program-
mers. The Telnet protocol uses simple ASCII text commands to
control and monitor the Architect Model 1601 SE amplifier.
To log into the Architect Model 1601 SE via Telnet, you need
a Telnet client program in your system. The factory default static
IP address of the Model 1601 SE is
192.168.0.1
and telnet is ac-
tive on port 23. The default user login ID and password are:
User ID: architect (note: all lower case)
Password: 900
An example of a typical telnet login session is:
/Telnet> login
/Telnet> UserID?: architect
/Telnet> Password?: 900
/Telnet> User authenticated!
/Telnet>
The serial ASCII control protocol over telnet allows simple
integration with other automation computer systems. The basic
command format is:
command<cr>
Where command is the ASCII text string of the command and
<cr> is an ASCII carriage return (0D hex) character as a com-
mand delimiter. These commands are case sensitive and have a
500mS timeout if no valid command or delimiter is sent.
26
Appendices
Caution
- Do not use
a speaker rated at
less than 8 ohms
when bridging. In
a bridged system,
each channel of the bridged pair
“sees” one half of the speaker load.
This means that a bridged amp
driving an 8 ohm speaker is actually
operating into a 4 ohm load.