Archgard 25-BVI20N-3 Скачать руководство пользователя страница 11

25-BVI20N 

3                                                     11 

PRECAUTIONS

 

• 

This appliance must be installed by a qualified gas installer and the installation must conform to the 

installation codes.

 

• 

This appliance needs fresh air for safe operation and must be installed so there are provisions for 

adequate combustion and ventilation air. Provide adequate clearance around air openings of the 

appliance. Never obstruct front openings.

 

• 

Provide adequate clearances for proper operation and servicing of the appliance.

 

• 

This appliance must be properly connected to a suitable venting system and must not be connected 

to a chimney flue serving a separate solid fuel burning appliance.

 

• 

This appliance is equipped with a three

-

prong (grounding) plug for your protection against shock 

hazard and should be plugged directly into a properly grounded three

-

prong receptacle.

 

The appliance is equipped with a vent safety shutoff system and a safety control system designed to 

protect against improper venting of combustion products. The appliance will not function without being 

connected to a proper venting system.

 

 

The draft hood must be installed in the same room as the atmospheric pressure zone as the combustion 

air inlet to the appliance and shall be located so that the relief opening is accessible for checking vent 

operation.

 

 

WARNING: 

 

Operation of this appliance when not connected to a properly installed and maintained 

venting system or tampering with the vent shut

-

off system can result in carbon 

monoxide (CO) poisoning and possible death.

 

 

This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.

 

The appliance may be vented using 4 in. diameter aluminum or stainless steel flexible gas liner running 

inside a masonry chimney or the flue of the factory

-

built fireplace. The vent system must be properly 

terminated with a suitable vent cap. The liner must form a complete connection from the flue collar to 

the vent cap. Follow the vent component manufacturer

s instruction. Also check with local gas 

authorities for proper venting methods and procedures.

 

 

Connecting the Vent Liner to the Appliance

 

 

Run the flexible gas liner down the chimney or flue. The appliance has a detachable flue adapter plate 

for ease of installation. Connect the the liner to the flue connector plate and fasten with screws and a

 4” 

gear clamp. Before placing the appliance into the fireplace, check the hearth of the fireplace to see if it is 

level with the front of the fireplace. If it is not, measure the depth of the hearth. Loosen the three screws 

of the leveling 

L

” 

bracket at the back of the appliance. Lower it to the measurement obtained and 

tighten the screws. Make sure the gas and electrical supply line are properly connected to the appliance. 

Slide the appliance into the fireplace, and at the same time, slide the flue connector plate back onto the 

top of the appliance. Check the leveling of the appliance and attach the faceplate to the appliance before 

sliding the appliance all the way into the fireplace.

 

VENTING

 

To install the Euro 25 into a vented gas fireplace, see APPENDIX A  (page 28) 

for installation instructions.

 

INSTALLATION INSTRUCTIONS 

-

 Continued

 

Содержание 25-BVI20N-3

Страница 1: ...and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave...

Страница 2: ...or of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accord...

Страница 3: ...thetics and heat output can be adjusted to suit the owner s moods and heating needs Solid Construction Constructed mainly of 16 and 18 gauge satin coated steel for long life and durability Please read...

Страница 4: ...ns 8 Log Placement 15 Operation Instructions 20 Maintenance 22 Troubleshooting Instructions 23 Servicing 25 APPENDIX A Installation Into Vented Gas Fireplaces 28 Suitable Host Fireplaces Specific Inst...

Страница 5: ...compartments burners and circulating air passageways for the appliance be kept clean Trim panels or surrounds shall not seal ventilation openings in the fireplace CAUTION FOR YOUR SAFETY Do not insta...

Страница 6: ...nstallation in a bedroom or a bedsitting room and conforms to CR89 001 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National...

Страница 7: ...S BAY GLASS DOOR REMOVABLE CONTROL COVER SURROUND FRONT VIEW SPARKER APPLIANCE DIMENSIONS A B I K J A 30 768 mm B 23 584 mm C 15 387 mm D 11 286 mm E 4 102 mm F 19 489 mm G 5 127 mm H 5 146 mm I 24 61...

Страница 8: ...y factory built wood burning and specific zero clearance vented gas fireplaces Due to constant additions contact Archgard Industries for an updated list of suitable gas fireplaces This appliance canno...

Страница 9: ...esult in property damage or personal injury The installer must mechanically attach the following warning included in the manual bag to the inside of the fire box of the fireplace into which the gas fi...

Страница 10: ...ust not be removed or altered side and top of door frame side and top of the face of fireplace metal sides etc If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2...

Страница 11: ...ng and possible death This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance The appliance may be vented using 4 in diameter aluminum or stainless steel...

Страница 12: ...flat tip screw driver and placing a test gauge on the tap The minimum permissible gas supply pressure is 4 5 in w c 1 2 kPa for natural gas and 11 0 in w c 2 8 kPa for propane Maximum gas supply press...

Страница 13: ...es on the bracket that best suit your application INSTALLATION INSTRUCTIONS Continued 1 2 3 The spill switch is manual reset type that can be reset by pressing the pin between the two wire terminals w...

Страница 14: ...bottom of the door towards you Lift up the door to unhook it from the body Place the door at a safe location where it cannot be scratched or damaged Replacing the Glass Door Installation of the glass...

Страница 15: ...an the amount and type supplied with the unit LOG PLACEMENT WARNING Do not place the logs or branches in any configuration other than the one shown A fire explosion or excessive carbon monoxide CO may...

Страница 16: ...rt using locator pins and pre drilled holes in log Log will sit as shown in the photo below STEP 2 Locate log 2 and place onto the left side of the burner using locator pins and pre drilled holes in l...

Страница 17: ...er using the locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 4 Locate log 4 and place onto right side of burner using the locator pins and pre drilled holes in lo...

Страница 18: ...he locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 6 Locate log 6 and place onto rear log using the locator pins and pre drilled holes in log Log should sit behin...

Страница 19: ...place onto rear log using the locator pins and pre drilled holes in log Log should sit behind left grate tine as shown in photo below FINAL LOG PLACEMENT Please note that all logs should be placed ex...

Страница 20: ...lt in a fire or explosion BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SME...

Страница 21: ...ing of pilot Press slightly and turn control knob counterclockwise to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place at the pilot...

Страница 22: ...gular services listed above Inspect and operate the pressure relief mechanism door buckles to verify they are free from ob struction and operate properly Carefully remove the logs and gently brush off...

Страница 23: ...ay be blocked or the gas valve may be defective 5 Check wiring and connections to spill switch Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob...

Страница 24: ...for correct ohms reading Replace if required 7 Check for proper drafting of the appliance Correct if drafting is occurring into the room 8 Spill switch has tripped Reset by hand when appliance has coo...

Страница 25: ...CING UNDER WARRANTY Remove the control cover The pressure test taps are located on the front of the valve The supply pressure is marked IN and the manifold pressure is marked OUT There is also an arro...

Страница 26: ...now visible Use a 11 32 hex socket and remove the three nuts holding the fan to the back of the firebox Disconnect the spade connectors to the fan Carefully remove the fan Reverse the above instructio...

Страница 27: ...r tray by loosening and removing the two mounting screws located next to the two back log locating tabs Shut of the gas to the appliance and disconnect the gas line to the appliance If the appliance h...

Страница 28: ...n updated list of gas fireplaces and any additional installation instructions The host gas fireplace s certification will be nullified and will no longer be usable for its original purpose A warning p...

Страница 29: ...ox Remove or trim any baffles inside the firebox that may be obstructing the direct passage to the flue connector Remove or trim any decorative facing or baffles inside the firebox that may interfere...

Страница 30: ...O 25 as it is being inserted into the host fireplace Level the EURO 25 as described in manual Complete the installation of the surround and accessories as described in the manual Check for proper vent...

Страница 31: ...personal injury or loss of life SAMPLE MODIFICATION WARNING PLATE 303 0050 WARNING This fireplace has been modified for use with the Archgard EURO 25 gas insert Usage without the EURO 25 gas insert m...

Страница 32: ...on of the host gas fireplace is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 7 Use Ar...

Страница 33: ...of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 6 Use Archgard 25 ICKIT5 connector kit to connect the insert to...

Страница 34: ...also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the hos...

Страница 35: ...is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector k...

Страница 36: ...chgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the host s vent cap Optional custom surround is availabl...

Страница 37: ...NAME ADDRESS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER 25 BVI20N 3 SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE Robertshaw 7000MVRB DATE PURCHASED INSTALLATION INSTAL...

Страница 38: ...ve When calling for help please have the following information Model of your Fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty may be void if work is carried...

Страница 39: ...0044 SPILL SWITCH 350 F MANUAL RESET 1 EA 305 0027 SWITCH BLANK ON OFF CARLING 9711 1 EA 308 0005 PIEZO IGNITOR c w NUT JBS 66270 003 1 EA 308 0043 VALVE 7000MVRB 5LC NG c w KNOB 1 EA 308 0093 PILOT A...

Страница 40: ...25 BVI20N 3 40 NOTES...

Страница 41: ...ler s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this wa...

Страница 42: ......

Страница 43: ...25 BVI20N 3 43 NOTES...

Страница 44: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...