25-BVI20N
–
3 10
INSTALLATION INSTRUCTIONS
-
Continued
Flue connector
straight
-
up vent
Flue connector
offset vent
Flue connector
straight
-
up vent
Flue connector
offset vent
MINIMUM ZERO
-
CLEARANCE WOOD BURNING FIREPLACE DIMENSIONS
17” (432
mm)
25” (635
mm)
12” (305
mm)
TOP VIEW
15
¼
” (387
mm)
X
Y
Z
SIDE VIEW
The standard flue adapter will fit if
X
is more than 5
¾
”.
It will also fit if
X
is less than 5
¾
”
but
Y
is
higher than
8”
(See
‘
Flue connector, offset vent
’
diagram)
Cutting any sheet
-
metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited except
as outlined in Appendix A of this manual. Any structured rigid frame member must not be removed or altered (side
and top of door frame, side and top of the face of fireplace, metal sides, etc.).
If the factory
-
built fireplace has no gas access hole(s) provided, an access hole of 1
1/2” (38.1
mm) or less may be
drilled through the lower sides or bottom of the firebox in a proper workmanship
-
like manner. This access hole must
be plugged with noncombustible insulation after the gas supply line has been installed.
The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert. The fire-
place and fireplace chimney must be clean and in good working order and constructed of noncombustible materials.
The chimney clean
-
outs must fit properly. The grate with logset must be removed. The smoke shelf, internal baffles,
screen, masonry lining or refractory, and metal or glass doors may be removed.