10.2. The principle of the system output:
Control signal = 0 switch/relay connected (24 V loop formation, low effective signal)
Control signal = 1 switch/relay disconnect (24 V did not form a loop, cancel)
10.3. Input/output connect definition
Detailed explanation:
Signal
Definition
BD
25core
Detailed explanation
>W+
1
Input
X/Y + limit, two axes is limit concatenated, high effective. If
you don't use, please send short signal received 24 V, if do
not use the limit, it is a bump shot detection (normally
closed).
W-<
14
X/Y - limit, limit concatenated two axles, high effective. If you
don't use, please send short signal received 24 V.
SX0/DUP
2
SX0 mechanical origin, NPN proximity switch, normally is
open. Reset the direction is invalid when the mouth for
external cutting up key, high effective, if you don't use, please
send short signal received 24 V.