IGNITION——It is the time delay when turn on the high voltage ignition switch if M20 is executed in flame
cutting operation.
HOTUP TIME——It is the preheating time for piercing operation in second. If the preheating time is
insufficient, it will be prolonged to 150 seconds automatically by pressing [PAUSE] key. If preheating is done
in the midway, Press [START] key to abort the time delay. The new preheating time will be automatically
saved in the parameter of preheating delay.
TORCHUP TIME(M70)——Torch rising time The time delay when M70 command is executed in second.
Refer to 6.4 for M auxiliary commands.
TORCHDN TIME(M71)——Torch down time, The time delay when M71 command is executed, in
second. Refer to 6.4 for M auxiliary commands.
PIERCEUP HIGH(M72)——Torch rising time after pierce The time delay when M72 command is
executed, in second. Refer to 6.4 for M auxiliary commands.
PIERCEDN HIGH(M73)——Torch falling time after pierce The time delay when M73 command is
executed, in second. Refer to 6.4 for M auxiliary commands.
PIERCE TIME——Lowering delay of cutting torch when M07 is executed in flame piercing
operation after cutting oxygen valve is opened.
OVER CUT DELAY-TIME----
Automatically disconnect oxygen delay;
After turning off the cutting
oxygen, due to the residual pressure in the tube, after this delay, proceed to the next step to
improve the cutting surface finish.
LINE DELAY-TIME--- After the program line is in place, after this delay time, run the next line
Move to the next piercing point after completing a cut.
SELECT HI HOTUP M24 (0/1)---
When the thick plate is perforated, the high preheating aid is
required. When this function is selected, M24 is turned on during preheating, and M24 is closed
after preheating. Note: When this option is not selected, M24 (preheating) will not be turned off
during the entire processing.
1 is to choose, 0 is not to choose;
GAS ON M ORDER---
Open the output port address used by the gas solenoid valve (see
diagnosis function),