Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
52
Torch positioning delay, M commands for arc ignition, M commands for arc breaking, arc
voltage test option, positioning test option and piercing delay.
Control parameters
Flame/plasma mode selection, machining speed limit, MOVE HOLE option, metric/English
selection, etc.
Save
Save the modified parameters into parameters space.
Continuous pressing S key, optional external manual control key and manual enable/disable option.
Notes:
When selecting the above parameters, it is required to save the change separately by pressing [F8] key
for validation.
If the password of "1928" is entered in the main window of SETUP, the saving menu of [F8]
will turn to factory setting. In this mode, every modification to parameter will be saved into the
factory setting parameters and the active user parameters. When initializing parameters, it is
suggested to set the factory parameters as active parameters; otherwise, the modifications will
be validated to the active user parameters.
7.2. SETUP(parameter setting)
7.2.1 Speed parameters
In the SETUP, press [F1] key to enter speed parameters setting window, as shown in Fig. 7.2