Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
61
INITIAL CLEAR COOR (0/1)---
Whether to automatically clear the coordinates before processing; Select 1,
before processing, automatically clear the coordinates to 0;
SELECT CYLINDER UP/DOWN (0/1)---
Pneumatic lifting torch,
Used in thin plate processing; 0 is not to
select pneumatic, 1 is to select pneumatic;
SELECT AUTO-REFERENCE (0/1)--- Automatically return parameters after processing-select. Select 1 to
automatically return to the reference point after processing.
LIMIT POSI EFFECT (0/1)---
External electronic limit is valid. Set to 0 = external electronic limit is valid, Set to
1 = external electronic limit is invalid.
SOFTWARE LIMIT EFFECT (0/1)---
Software limit is valid. Set to 0 = CNC-software limit is invalid, Set to 1 =
CNC-software limit is valid.
CHECK COLLIDE (0/1)---Collision torch detection is effective. When the machine has an anti-collision device,
this parameter needs to be set; if THC can control the anti-collision signal, this parameter does not need to
be set; Collision cutting torch detection valid=1, In case of collision, the system will immediately pause (and
report collision warning);
COLLIDE-LOCATE SAME PORT (0/1)---
Whether the torch collision detection and positioning detection are
the same input port-select. 0 is the same, 1 is different;
COLLIDE PAUSE (0)/TORCHUP (1)---
System pause/raise after torch hit. Set= 0, processing will be
suspended after the torch is hit, Set=1, Automatically raise the torch after hitting the torch, and the
processing continues.
PAUSE UP TORCH (0/1)---
Raise the torch after pause (0/1) select; Set to 1, after the pause, there will be a
raising torch action.
CUTTING LINE (BREAK.MM)---
Cutting length (set breaking point. mm) —— When the bridge breaking
function is selected during processing, each time this length is cut, the system will automatically set a
breaking point;
BRIDGE CUTOFF LINE (MM)---
Length of broken bridge (mm) —— After setting the broken bridge point,
After running this distance; Restart cutting;