background image

 

ARCADIA Fire Company - Srl/GmbH - Via Enrico Fermi Straße 11 - 39100 - Bolzano / Bozen (BZ)

 

 

 
 

Installation instructions 

 

Vita Systeme 

 
 
 
 
 
 
 
 
 

 

Vita System angolo 39/58 

 

Vita System angolo 58/39 

 

Vita System angolo 45/45 

 

Vita System frontale 45 

 

Vita System frontale 60 

 

Vita System frontale 80 

 
 
Version dated: 09/2014 
 
 

Содержание Vita System angolo 39/58

Страница 1: ...mi Stra e 11 39100 Bolzano Bozen BZ Installation instructions Vita Systeme Vita System angolo 39 58 Vita System angolo 58 39 Vita System angolo 45 45 Vita System frontale 45 Vita System frontale 60 Vi...

Страница 2: ...on air side connection 6 10 Flue side connection 8 11 Flue and combustion air connection dimension sheet 8 12 Fire protection 14 12 1 Floor coverings near the fireplace 14 12 2 Radiation protection 15...

Страница 3: ...errors Symbol key 2 A variety of symbols are used in these instructions Observance of these symbols is of central importance to ensure the correct planning installation and operation of this product F...

Страница 4: ...s expedient that you attach a protective fixture for these groups of persons as the view pane and the cladding parts of the fireplace can become extremely hot Risk of burning Never leave these groups...

Страница 5: ...l characteristics of concrete in terms of surface and appearance In spite of great care taken during production and transport slight irregularities small cracks or rough edges cannot be completely eli...

Страница 6: ...ll be necessary to make a cut out in an element of the system For this purpose there is a recess in the right position on the inside of the cladding element which must be opened beforehand Proceed as...

Страница 7: ...the sawing smooth the edges and then clean up the surface with non woven abrasive if necessary It is a good idea to protect the cut out contour with tape in order to prevent the edges from breaking of...

Страница 8: ...llation process In this case disassemble the elbow and put it aside for subsequent installation The storage elements must be cut out to enable a rear flue gas connection To make the cut out proceed as...

Страница 9: ...9 Vita System frontale 45 SX DX Vita System frontale 45 SL...

Страница 10: ...10 Vita System frontale 60 SX DX Vita System frontale 60 SL...

Страница 11: ...11 Vita System frontale 80 SL...

Страница 12: ...12 Vita System angolo 45 45 SX DX Vita System angolo 45 45 SL...

Страница 13: ...13 Vita System angolo 39 58 DX SL Vita System angolo 58 39 SX SL...

Страница 14: ...ble materials The covering must extend from the combustion opening by at least 50 cm to the front and at least 30 cm to the sides The non flammable covering may be made of ceramic such as tiles or fla...

Страница 15: ...s prevents thermal stress points from forming and adjoining components becoming heated to an impermissible degree Radiation protection sheets for wall connections are available as an accessory As an a...

Страница 16: ...16 Free standing installation mode Vita System angolo 45 45 58 39 39 58 5cm 50cm 15cm...

Страница 17: ...17 12 4 Distances to flammable installation walls Wall flush installation mode for Vita System frontale 45 60 80 Only permissible when a radiation protection sheet is used 50cm 15cm...

Страница 18: ...18 Wall flush installation mode for Vita System angolo 45 45 58 39 39 58 Only permissible when a radiation protection sheet is used 50cm...

Страница 19: ...process on the Vita System frontale 60 SL model but the same process can be used on the other models Separate instructions are provided for device specific exceptions on other models Inspect the syst...

Страница 20: ...element must be completely pushed up against the installation wall Special instructions on the Classic corner decoration elements in the case of wall flush installation If the Classic corner decorati...

Страница 21: ...by at least 2 persons Now align the fireplace insert at the front and adjust it to the suitable height Observe the dimensions specified in the white boxes below Connecting the combustion air duct Onc...

Страница 22: ...1 is installed The connection of the individual system modules to each other can be reinforced with mortar or heat resistant silicon adhesive In the case of the cladding version equipped with a heart...

Страница 23: ...ounts provided for fastening the screen must be screwed onto the fireplace insert after cladding elements 1 2 have been installed To accomplish this attach the angled steel profiles to the body as sho...

Страница 24: ...ended for it In this case the hearth must be positioned beneath the sill of the fireplace insert In doing so pay attention to the horizontal and vertical fitting and reinforce the seams with adhesives...

Страница 25: ...ase of a rear connection the upper cladding element must be cut out for the flue pipe To do this follow the instructions for the flue side connection in these instructions The connection of the indivi...

Страница 26: ...Vita System delivery and must be ordered separately Installing the radiation protection sheets There are retainers for fastening included with each radiation protection sheets These must be attached t...

Страница 27: ...ust be loosened and the removed upward Adjust the connection line in length a the necessary length varies depending on the distance from the wall and completely press it into the wall lining of the ch...

Страница 28: ...ection direction the connection pipe may only be inserted after the top plate has been put in place Installing the corner elements The Vita Systems corner elements may be attached using conventional m...

Страница 29: ...r frame onto the fireplace insert and readjust the combustion chamber frame if necessary Storage elements 2 5 must end parallel to the screen To do so insert the combustion chamber frame straight into...

Страница 30: ...st be placed onto the system When doing so make sure that it fits flush to the cladding elements The dummy cover for the flue gas connection on top must be removed before the top plate is placed on an...

Страница 31: ...ying the plaster to the surface Dampen the surfaces with a sponge so that the bonding finish to be applied can take a good hold on the stone surface The processing temperature must be 10 C To prevent...