The following table indicates the values for enabling the probes based on the type of water circuit used:
System
configuration
[P37]
Description
Water probes used
Pumps used
Heating only
Boiler outlet probe S4
Boiler return probe S5
System pump (PI)
Anti-condensation pump (PR)
H DHW
storage cylinder
Boiler outlet probe S4
Boiler return probe S5
DHW cylinder top probe S3
System pump (PI)
Anti-condensation pump (PR)
DHW cylinder pump (PB)
H Buffer
tank / Combi buffer
tank
Boiler outlet probe S4
Boiler return probe S5
Buffer tank top probe S3
Buffer tank bottom probe S2
System pump (PI)
Anti-condensation pump (PR)
Buffer tank pump (PB)
H
DHW storage
cylinder
+ Solar panels
Boiler outlet probe S4
Boiler return probe S5
DHW cylinder top probe S3
DHW cylinder bottom probe S2
Solar panel probe S1
System pump (PI)
Anti-condensation pump (PR)
DHW cylinder pump (PB)
Solar panel pump (PS)
H
Buffer tank +
Solar panels
Boiler outlet probe S4
Boiler return probe S5
Buffer tank top probe S3
Buffer tank bottom probe S2
Solar panel probe S1
System pump (PI)
Anti-condensation pump (PR)
Buffer tank pump (PB)
Solar panel pump (PS)
7.2. Display menu (display probe readings)
The display menu shows the values read by the
probes enabled on the control unit.
The top display shows the value of the selected
probe.
The bottom display shows the code identifying the
probe.
PROCEED AS FOLLOWS:
1) Press MENU.
2) Press button 3 repeatedly until the top display shows DISP.
3) Press MENU.
4) The bottom display shows the parameter being
set, while the top display shows its value.
5) Scroll the parameters using buttons 3 and 4.
6) Press ESC to exit or wait 40 seconds to automatically exit the menu.