14
9.3
JOB SETTING
Set the values corresponding to the machine.
9.3.1
Number of rows
Set the number of rows you wish to use.
Job settings
Row width
Rows number
4
Application rate
1) Access the row number set-up menu (Settings menu > Job set-up > Number of rows).
The display will show the current value below the selected item.
Press
OK
to edit the selection of the number of rows.
Rows number
Min Value
Max Value
1
16
4
0
C
D
B
A
2) Set the value of the number of rows:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes.
Possibilty to connect up to 4 ORION MULTIFLOW flowmeters and able to read the data of 16 channels at the same time.
9.3.2
Inter-row width
Set the inter-row width.
The inter-row width corresponds to the distance between the application points.
1) Access the inter-row width set-up menu (Settings menu > Job set-up > Inter-row
Width).
The display will show the current value below the selected item.
Press
OK
to edit the selection of the inter-row width.
2) Set the value of the inter-row width:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes.