Application rate alarms
Set the desired alarm display thresholds for minimum and maximum application rate.
Minimum and maximum application rate alarms are set in the same way.
Alarms
Min speed
Min App. rate
OFF
Max speed
1) Open Alarm menu (Setup menu > Alarms).
The display will show the current setting below the selected item.
Press
OK
to edit the selected menu item.
Min App. rate
Min Value
Max Value
1.0
1000.0
OFF
o
2) To activate the alarm, press
and
at the same time until message
OFF
goes
off and application rate alarm value is displayed instead.
Carry out the same procedure to disable alarm again.
C
B
D
A
Min App. rate
Min Value
Max Value
1.0
1000.0
001.0
0
l/ha
o
3) Set alarm value:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes .
9.1.4
Flowmeter status alarms
Enable/disable the alarm corresponding to flowmeter status.
Flowmeters status
ON
Alarms
Min App. rate
Max App. rate
1) Open Alarm menu (Setup menu > Alarms).
The display will show the current setting below the selected item.
Press
OK
to edit the selected menu item.
9.1.5
Alarm activation delay
Alarm act. delay
2.0s
Alarms
Max App. rate
Flowmeters status
1) Open Alarm menu (Setup menu > Alarms).
The display will show the current setting below the selected item.
Press
OK
to edit the selected menu item.
Alarm act. delay
Min Value
Max Value
1.0
5.0
.0
1
C
D
B
A
s
2) Set the alarm activation delay:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes.