24
Par.10.2
Shifting
of the cursor
Quits the menu or
the data change
Confirms access to menu
or data change
Menu item scrolling or
Data increase/decrease
ADVANCED SETUP
Calib. phase
Activate Main
9
10
ON
Calib. phase
In progress...
Calib. phase
Complete
11
9
Immediately after that, the computer passes to the calibration start screen:
the display shows the message
Calib. phase
>
Activate Main
.
10
Start the spraying system: open, in succession, ALL section valves and the main
control (switches in position
ON
).
The display shows the message
Calib. phase
>
In progress...
.
Press
ESC
to interrupt the calibration without saving.
11
When the rate value reaches zero and remains so for at least 10 s,
Bravo 180S automatically finishes the procedure and displays the message
Calib. phase
>
Complete
.
Press
OK
: the calibration is finished and saved and replaces the current calibration.
After having completed the calibration and checked the sensor correct operation, we recommend to memorise the calibration on pendrive
(menu
Tank profile
>
Save
>
0 calibration
*
It activates the "zero" calibration procedure of level sensor.
If a fluid is detected in the tank even if it is empty, it is necessary to calibrate the level sensor zero.
- Press
OK
to reset the sensor residual signal.
Check sensor!
Faulty values detected: check the sensor operation.
If problem persists, check for residual fluid in the tank.
0 calibration
4.000 mA
Fig. 54
>
Tank profile
*
The level sensor calibration can be loaded or saved on pendrive to reconfigure the device if necessary, solve
problems, or configure another Bravo 180S without having to repeat all operations.
Before any other operation, insert the pendrive in its slot (par. 7.2).
Tank profile
. . .
Fig. 55
>
Save
: select this option and press
OK
.
The confirmation message
Ok TANK.TKL
is displayed once the saving process is completed.
USB not found
Saving alarm: pendrive not inserted.
>
Load
: select this option and press
OK
.
The confirmation message
Ok TANK.TKL
is displayed once the configuration process is completed.
USB not found
File not found
Configuration alarms:
• Pendrive not inserted.
• The tank configuration
TANK.TKL
is not saved on the pendrive.
Tank source
>
Level Sensor
par. 11.16
* MENU VISIBLE ONLY WITH SPECIFIC SETTINGS:
TO VIEW IT, ENABLE THE INDICATED OPTION.
11.18
Spraying Menu
Spraying Menu
Large
Fig. 56
Upon spraying it is possible to display and check in real time the current spraying data.
BRAVO 180S can display such data in extended or short mode.
The table indicates the two display modes:
Data
extended
short
Pressure sensor
par. 11.12
Press. calc.
par. 11.14
** MENU VISIBLE ONLY WITH SPECIFIC SETTINGS:
TO VIEW IT, ENABLE ONE OF THE INDICATED OPTIONS
Speed
•
•
Pressure
**
•
•
Flowrate
•
•
Surface
•
•
Sprayed fl.
•
•
Tank level
•
--
Time
•
--
Distance
•
--