background image

Wood burning air control position 

 

 

 

Fully Closed 

 

 

 

 

Fully Open 

11 

DEFRA Stove  Installation and User Guide 

USER GUIDE

 

Solid fuel burning air control position 

 

 

 

Fully Closed 

 

 

 

 

Fully Open 

Images of a Generic Stove

 

Содержание Aarrow DEFRA

Страница 1: ...A Stove Installation and User Guide BK575 February 2013 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE EN 13240 2001 Amd A2 2004 For stoves ranges Aarrow DEFRA Signature DEFRA Ecoburn DEFRA Solution DE...

Страница 2: ...td T 0845 634 5626 W www hetas co uk A fireguard conforming to BS 8423 2002 should be used in the presence of children and old or infirm people Do not use aerosol sprays or any other flammable materia...

Страница 3: ...material This gap must be at least 3X the outside diameter of the flue pipe or 1 5X the flue diameter to non combustible surfaces INSTALLAITON INSTRUCTIONS DEFRA Stove Installation and User Guide 3 A...

Страница 4: ...e uses firebox liner panels at both sides of the stove The throat plate is not supported by these liners however the throat plate must be installed before the liners can be fitted and the liners remov...

Страница 5: ...ected to a suitable and efficient flue so that products of combustion fumes from the stove are expelled to the outside air To ensure a good up draught it is important that the flue gases are kept warm...

Страница 6: ...the horizontal section should not exceed 150mm 6 in length If the stove appears to be working hard but produces very little output to the room it is likely that excess draw is present in the chimney a...

Страница 7: ...ce or chimney your wood is Green or too wet Please Note The burn classification for all appliances in these instructions are classed as intermittent use Paper Paper will burn successfully Burn dry pap...

Страница 8: ...to maximum When the logs have burnt down to embers the Ignition Sequence is complete and re fuelling for normal use can commence The purpose of these ignition instructions lighting from cold is to ens...

Страница 9: ...r Firing and Chimney Fires Do not over fire your appliance Using flammable liquids or too much wood or firing the stove at maximum for prolonged periods may result in over firing If the chimney connec...

Страница 10: ...h the throat plate arrangement The air control is fully adjustable but has two main settings in normal use 10 Multi Purpose Operating Tool Your stove is supplied with a multi purpose operating tool us...

Страница 11: ...ood burning air control position Fully Closed Fully Open 11 DEFRA Stove Installation and User Guide USER GUIDE Solid fuel burning air control position Fully Closed Fully Open Images of a Generic Stove...

Страница 12: ...www arada uk com www aradastovesandspares com Height Width Depth Code kW Output Height Width Depth Flue Diameter Net Efficiency Rear Side Height to centre of rear flue Depth from back to centre of top...

Отзывы: