background image

Air Controls 

Our DEFRA stoves have one air inlet  
control for easy operation.  

The air inlet provides air through the base of 
the stove, via the control slider located under 
the base of the door.  

The air passes from the base of the stove, 
through a sealed airway, around the back 
and top of the fire box providing a very hot air 
flow over the fire bed.  

Secondary air also enters the fire box through 
a pre-set bleed at the rear of the stove, and is 
heated and distributed through the throat 
plate arrangement. 

The air control is fully adjustable but has two 
main settings in normal use.  

10 

Multi Purpose Operating Tool 

Your stove is supplied with a multi purpose  
operating tool, used for adjusting the air inlet 
controls and the removal of the ash pan 

 

Emptying the Ash pan 

Your stove is supplied with a unique ash pan. To 
empty or remove the ash pan, open the fire 
door(s), fit the fork end of the operating tool 
into the ash pan slots and remove from the ash 
pit chamber. 

Empty the ash into a suitable container and  
replace the ash pan into the stove, withdraw 
the operating tool and close the fire door. 

DEFRA Stove  Installation and User Guide 

USER GUIDE

 

Содержание Aarrow DEFRA

Страница 1: ...A Stove Installation and User Guide BK575 February 2013 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE EN 13240 2001 Amd A2 2004 For stoves ranges Aarrow DEFRA Signature DEFRA Ecoburn DEFRA Solution DE...

Страница 2: ...td T 0845 634 5626 W www hetas co uk A fireguard conforming to BS 8423 2002 should be used in the presence of children and old or infirm people Do not use aerosol sprays or any other flammable materia...

Страница 3: ...material This gap must be at least 3X the outside diameter of the flue pipe or 1 5X the flue diameter to non combustible surfaces INSTALLAITON INSTRUCTIONS DEFRA Stove Installation and User Guide 3 A...

Страница 4: ...e uses firebox liner panels at both sides of the stove The throat plate is not supported by these liners however the throat plate must be installed before the liners can be fitted and the liners remov...

Страница 5: ...ected to a suitable and efficient flue so that products of combustion fumes from the stove are expelled to the outside air To ensure a good up draught it is important that the flue gases are kept warm...

Страница 6: ...the horizontal section should not exceed 150mm 6 in length If the stove appears to be working hard but produces very little output to the room it is likely that excess draw is present in the chimney a...

Страница 7: ...ce or chimney your wood is Green or too wet Please Note The burn classification for all appliances in these instructions are classed as intermittent use Paper Paper will burn successfully Burn dry pap...

Страница 8: ...to maximum When the logs have burnt down to embers the Ignition Sequence is complete and re fuelling for normal use can commence The purpose of these ignition instructions lighting from cold is to ens...

Страница 9: ...r Firing and Chimney Fires Do not over fire your appliance Using flammable liquids or too much wood or firing the stove at maximum for prolonged periods may result in over firing If the chimney connec...

Страница 10: ...h the throat plate arrangement The air control is fully adjustable but has two main settings in normal use 10 Multi Purpose Operating Tool Your stove is supplied with a multi purpose operating tool us...

Страница 11: ...ood burning air control position Fully Closed Fully Open 11 DEFRA Stove Installation and User Guide USER GUIDE Solid fuel burning air control position Fully Closed Fully Open Images of a Generic Stove...

Страница 12: ...www arada uk com www aradastovesandspares com Height Width Depth Code kW Output Height Width Depth Flue Diameter Net Efficiency Rear Side Height to centre of rear flue Depth from back to centre of top...

Отзывы: