background image

120

 - Holding the Menu key for more than 5 seconds

will recover the source data.

121 -The schedules of calendars 1 and 2, as well as

the hours of operation and lit, will be maintained.

In case there is no graphic representation on the display, we can perform the data recovery, following

the instructions below

Disconnect the stove. Keep the increment key pressed and then connect the stove again without releasing the

increment key.

 After a few seconds, a numerical representation corresponding to the data that is being recovered will

appear. Release the increase key.

Adjustment of combustion air. 

As we have already indicated on page number 5, the adjustment of the combustion air must be done as

carefully as possible.

 Once the stove is on and has reached the 

power level 5

, we enter the combustion air setting "

Menu 1- 6a

".

The flame must have liveliness without getting rid of fuel from the basket, that is, the flame must be vertical

but there must be too much air at the combustion point (basket).

We will observe that the tips of the flame tend to have an orange color without these traces of smoke. The

increase or decrease of the air level in the “

Menu 1-6a

”, it will be done varying 

+/- .01mB

  and waiting for next

30 seconds approximately

, so that the modified value stabilizes. Depending on the results, we will continue

the adjustment or conclude the same. It is very important that the duration of this regulation be at least 

15

minutes.

Observe when the stove is off and the cooling process is complete, if the bottom of the hearth has a grayish

color and no traces of dark areas, if so, combustion is proving satisfactory.

This regulation will remain 

permanently 

in the stove, so it is not necessary to modify it again. 

The Viriato cpu will self-regulate combustion air based on the fuel, power required and waste

accumulated during the operation of the stove.

If the minimum air required by our combustion is not reached, the stove will turn off indicating

insufficient air in the combustion.

 

16

Содержание UNICONTROL

Страница 1: ... environment before printing this document Content Pag 3 LCD Pag 4 5 Quick guide for start up Pag 6 7 Air water models Pag 8 16 Menu 1 Options and user settings Pag 17 18 Menu 2 Functions of the displayed data Pag 19 21 Incident messages Pag 22 Wifi Unicontrol Viriato 04 2019 ...

Страница 2: ...CPU UNICONTROL The Unicontrol device is a device designed to manage pellet stoves and boilers 2 Módulo WIFI Display LCD ...

Страница 3: ... sent by the remote control 7 LED DIODE indicates signal reception coming from the remote control 9 FLAT TAPE CONNECTOR Connect the keyboard with the UNICONTROL unit using flat cable 10 USB CONNECTOR Connect the keyboard with the UNICONTROL unit using a USB cable LIGHTING THE KEYBOARD ACTIVATE DEACTIVATE The keyboard models Uni_Teclado_11 and later versions have a function which allows us to deact...

Страница 4: ...equal to or greater than the value It is located on the right 53mB 5 Screen without activity Indicates that the stove is ready to light We press menu to see the programming 6 Basic program Modulation by fuel levels No control of ambient temperature or external temperature Quick guide to show the operation of the stove with rise and fall of the power level In menu 1 you will find the way to program...

Страница 5: ... has not yet been exceeded 13 Power level 5 reached and stabilized 14 We lower the power level The symbol indicates that the temperature is lowering 15 Minimum power level L When a level is lowering in temperature it can reach the minimum level depending on the thermal inertia of the stove 16 Power level 3 reached and stabilized 17 We increase power level The symbol indicates that the temperature ...

Страница 6: ...al probe allowing the stove to be turned on if the value of the external temperature is ower than the value programmed in menu 1 3 on week It is advisable that the installation of the external temperature probe be carried out by the technical service 21ºC 25ºC The temperature between angular brackets corresponds to the programmed value setpoint temperature The temperature on the right corresponds ...

Страница 7: ...tion of the external temperature probe be carried out by the technical service Indicates that the accelerator pump is activated 56ºC 58ºC The temperature between angular brackets corresponds to the programmed value setpoint temperature The temperature on the right corresponds to the temperature of the water accumulator In this same screen using increment or decrement keys we can modify the setpoin...

Страница 8: ...ons by examples The schedules and adjustments made in the Menu 1 they must be preceded by the key Menu When you press this an asterisk will appear which tells us that we can vary the selected option Once the adjustment has been made the memorization of it will be carried out whit the ON OFF key erasing the asterisk The only exception is found in the error selection sub menu since the change is mad...

Страница 9: ...and we pass with the menu key to the next sequence 32 We modify the day of the week 33 We left watch programming and selected weekly schedule 1 34 We enter weekly program 1 35 Ignition program These values will be repeated every day of the week We select time 36 No We modify the time and select the minutes 37 We modify the minutes 38 We select temperature 39 We modify temperature 9 ...

Страница 10: ...rature and modify its value 46 We leave weekly shutdown 47 We select the Monday program 48 Ignition program These values will be repeated every Monday The scripts indicate that there is no programming We select time 49 Using a decrement button we enable the time to modify it Yes in the hour we write 24 we disable the programming 50 We select the minutes 51 We modify the minutes 52 We select and mo...

Страница 11: ...nable the time to modify it Yes in the hour we write 24 we disable the programming 57 We select the minutes 58 We modify the minutes 59 We select temperature 60 We modify temperature 61 We left off Monday Tuesday Sunday they are scheduled in the same way as Monday 62 We select the ignition program on Tuesday 63 64 It is programmed in the same way as program 1 65 We enter the chronothermostat progr...

Страница 12: ... keep the ambient temperature stable and save our fuel 71 We enable thermostat 72 We confirm habilitation 73 We left thermostat 74 We select standby thermostat The stove will switch off if it exceeds 3ºC air or 7ºC water at ambient temperature setpoint boiler 75 We enable standby 76 We confirm habilitation 77 We left standby 78 We select fuel level programming 79 We enter fuel level programming 12...

Страница 13: ...optimal result We enter the combustion air programming 86 We select the air adjustment 87 We increase depression level 88 We confirm the adjusted level 89 We enter the convector air setting 90 The convector is a fan that extracts air from the bottom and back of the stove leading it through the heat exchanger to finally remove it from the upper front 91 We increase convection level Increases the ai...

Страница 14: ...nition 97 We enable the hardware test In the event that the electrical network is unstable this test should be disabled 98 We confirm hardware test enablement 99 We select keyboard sound 100 We enable keyboard sound There will be a short beep every time we press a key You will also hear beeping sequences when the stove is turned on and off 101 We confirm keyboard sound We confirm keyboard sound We...

Страница 15: ...will turn off again when the temperature is lower than the programmed value We confirm temperature 110 We left standby programming 111 We enter fuel selection 112 We select pellets 113 We enable selection 114 We select through the olive bone increment key 115 We confirm olive bone 116 We left the fuel selection 117 We select menu 1 11 118 Not used We select menu 1 12 119 Not used We select to reco...

Страница 16: ...t that is the flame must be vertical but there must be too much air at the combustion point basket We will observe that the tips of the flame tend to have an orange color without these traces of smoke The increase or decrease of the air level in the Menu 1 6a it will be done varying 01mB and waiting for next 30 seconds approximately so that the modified value stabilizes Depending on the results we...

Страница 17: ...ng on model 126 Upper line air depression incombustion millibars Bottom line ambient temperature boiler boilers only 127 Upper line percentageofoperationoftheextractor Línea inferior percentage of operation of the convector pump boilers only 128 Number of ignitions made 129 Total hours in operation 130 Maximum level of depression It serves as a reference to determine the amount of air that the sto...

Страница 18: ...142 First line date of revision Second line indicates the telephone number of the technical service The phone shown is by way of example it has no validity 142A The boiler stove was switched off due to excess temperature in the air exchanger It will light up again when the temperature drops one degree of the set value menu 1 9 142B The boiler has been turned off and will not turn on again until th...

Страница 19: ...ll indicate everything that is related to the incident 143 Badly inserted motor terminal or defective connection in the wiring Consult with technical service 144 Check the following points check the safety thermostat Check if the convector motor works broken worm motor or problem in connection Consult with technical service 145 Defective exhaust motor or connection problem Consult the technical se...

Страница 20: ...t must be well closed cleaning records they must be tightly closed Exhaust tubes can have excess soot 153 Check the probe connector located on the back of the stove 154 Check the following points that there are pellets inside the hopper that the worm motor is not blocked that the basket is clean that the safety thermostat is operational that the ignition resistance is operational 155 Thermocouple ...

Страница 21: ...tor it could be dirty poor ventilation in the environment of the stove 159 Check the following points exchanger and dirty smoke passes malfunction in convector it could be dirty poor ventilation in the environment of the stove 160 Check the following points expansion vessel with low pressure Lack of water in the circuit Supply water to the circuit through the load valve Check that the radiators do...

Страница 22: ...uiring the Uniwifi_19 device For more information register on our website and in the tab Download of documents select the document 1_Manual_wifi_19 The following images show some of the options that can be accessed through the web with the stove connected The images correspond to a boiler with sanitary water management 22 ...

Страница 23: ...23 ...

Страница 24: ...24 ...

Отзывы: