![AR 10013130 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/ar/10013130/10013130_operating-and-service-manual_2962272032.webp)
Model 2000TP2G8B
22
Rev -
Table 3-3. Catalog of IEEE-488 Commands
Command
Function
Units
Response format
RDSTAT
Returns status code of processing of previous command
(see Table 3-4)
STATUS=[ ]
RDFLT
Returns system fault code (see Table 3-5)
flt=[ ]
SYSTEM:ON;
Emulates pressing the System ON button from System
OFF (Exit Sleep Mode)
SYSTEM:OFF;
Emulates pressing the Power Save button. (Enter Sleep
Mode)
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK
Returns cathode voltage
KV
Ek=[ ]
RDEB
Returns collector voltage
KV
Eb=[ ]
RDEG
Return grid voltage
V
Eg=[ ]
RDEF
Returns heater voltage
V
Ef=[ ]
RDIF
Returns heater current
A
If=[ ]
RDIW
Returns helix current
mA
Iw=[ ]
RDTMPTWTF
Returns TWT temp (°F)
°F
TWTF=[ ]F
RDTMPTWTC
Returns TWT temp (°C)
°C
TWTC=[ ]C
RDTMPPSF
Returns power supply temp (°F)
°F
PSF=[ ]F
RDTMPPSC
Returns power supply temp (°C)
°C
PSC=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
SPSOTC
Sets p. s. overtemp warning setpoint (°C)
°C
RDIWOC
Returns helix overcurrent warning setpoint
mA
IwOC=[ ]
SIWOC
Sets helix overcurrent warning setpoint
mA
RDLOGIC
Returns logic state code (see Table 3-6)
Sys=[ ]
RDA
Returns gain
%
A=[ ]
SA
Sets gain
%
RDHTDREM
Returns remaining heater time delay
sec.
HTD=[ ]s
RDPODP
Returns forward power out (dBm) Peak
dBm
Po=[ ]dBm Pk
RDPOWP
Returns forward power out (W) Peak
watts
Po=[ ]W Pk
RDPOD
Returns forward power out (dBm) Average
dBm
Po=[ ]dBm Avg
RDPOW
Returns forward power out (W) Average
watts
Po=[ ]W Avg