Model 2000TP2G8B
16
Rev -
Menu screens
- The screens at the highest level are called menu screens. There are five menu screens. At
power on, the MENU 1 screen is displayed. Each of the menu screens has the soft key S4 labeled MORE.
The MORE key (S4) causes the next menu screen to appear. From MENU 5, MORE causes MENU 1 to
reappear. In short, MORE permits scrolling through the menu screens. The EXIT key returns display to
MENU 1 from any other menu screen.
The menu screens display system status and parameter levels. They are configured as follows:
Menu
Setting
MENU 1
Forward power Peak (watts or dBm)
Reverse power Peak (watts, dBm, or % of fwd power)
Duty
System status (if a latched fault exists, MENU 1 is displayed with the system shutdown message)
Band Switching (LOW/HIGH) (Visible in Standby mode only, this enables the user to manually switch to LOW
band or HIGH band when using external harmonic filters and switches - only on models with optional external
harmonic filter / switch assembly.)
MENU 2
Forward power Average (watts or dBm)
Reverse power Average (watts, dBm, or % of fwd power)
Duty
System status
MENU 3
Console hours (active when AC power is on)
Operate hours (active when HV is on)
MENU 4
Inside cabinet temperature (°C or °F)
TWT baseplate temperature (°C or °F)
MENU 5
Heater voltage (Ef)
Heater current (If)
Collector voltage (Eb)
Grid voltage (Eg)
Cathode voltage (Ek)
Helix current (Iw)
Help Screens
- On each of the menu screens, soft key S3 is labeled HELP. If S3 is selected, a message
describing the functions of that screen will be displayed. Use the ADJUST knob to scroll through the
message. The EXIT key will return you to the screen from which the help screen was called.
Setup Screens
- From MENU 2, S1 (labeled SETUP) selects the first of several setup screens, SETUP 1.
This allows the user to manually shut off the heater power supply and put the HPA into “Sleep Mode”.
Pressing S1 (SET) toggles between On and OFF. Pressing MORE brings up the SETUP 2 screen. This
toggles display of temperature parameters between Fahrenheit and Celsius degrees. Pressing S1 (SET)
changes the selection. The setting displayed when the screen is exited will be retained. Pressing MORE
again brings up the SETUP 3 screen, which allows a choice of displaying forward power in dBm or watts.
Pressing MORE again brings up SETUP 4, which allows a choice of dBm, watts, or % of forward power for
displaying reflected power. Pressing MORE again brings up SETUP 5, which allows entering the desired
number of alarm beeps and the desired beep volume. S1 (SET) toggles between parameters, and the adjust
knob is used to enter the data. Pressing MORE again brings up SETUP 6, which allows the IEEE-488
address to be set. Pressing MORE again brings up SETUP 7, which allows setting the auto heater off time
delay in 30 minutes intervals up to 3 hours. S1 (SET) changes the settings. Pressing MORE returns you to
SETUP 1. EXIT returns you from any of the setup screens to MENU 2.