![AR 1000S1G6C Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/ar/1000s1g6c/1000s1g6c_operating-and-service-manual_2962344021.webp)
Model 1000S1G6C
3
Rev A
1.5.2
Power
The Model 1000S1G6C offers a low and high voltage option for operation.
Low Voltage Option
High Voltage Option
Minimum
Maximum
Unit
Minimum
Maximum
Unit
200
240
VAC
380
415
VAC
47
63
Hz
47
63
Hz
Power Consumption: 8.5 kW
Power Consumption: 8.5 kW
CAUTION:
Dangerous voltages are present in the Model 1000S1G6C whenever the unit
is plugged into an AC outlet. Always disconnect the unit from the main
power line when servicing it. Please note that neither the Keylock Switch
nor the POWER button will completely shut off the unit’s AC power.
Due to the variety of power systems available internationally, the line cord is not supplied with a power plug.
The user must determine and install the appropriate AC power plug to the unit. Depending on facility power,
the amplifier can be wired using either of the two methods shown below.
Low Voltage Option, Delta 4-wire
High Voltage Option, Wye 5-wire