![AR 10006896 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/ar/10006896/10006896_operating-and-service-manual_2962263036.webp)
Model 500T2G8
24
Rev E
Table 3-6. Catalog of System State Codes
(The
RDLOGIC
command causes the TWTA to send a string containing an operational state code consisting
of 4 ASCII characters representing hex digits. The response is in the form
Sys=[w][x][y][z][eol]
where the
hex values of
[w],[x],[y] and [z]
are formed as shown below)
z bit
Meaning
0 (LSB)
High voltage on
1
Transmit on
2
Remote mode
3 (MSB)
Fault
y bit
Meaning
4 (LSB)
Heater time delay expired
5
Under forward power warning
6
Foldback active
7 (MSB)
Inhibit mode
x bit
Meaning
8 (LSB)
External inhibit
9
Interlock open
10
(not used)
11 (MSB)
(not used)
w bit
Meaning
12 (LSB)
(not used)
13
Sleep Mode Active
14
(not used)
15 (MSB)
(not used)
Table 3-7. *STA?; Response Codes
(The command
*STA?;
causes the TWTA to send a string indicative of the current system state)
*STA?; response
Meaning
SLEEP
Sleep Mode active (heater off)
WARM-UP
System is in heater time delay.
STANDBY
System is ready to allow high voltage on
OPERATE
High voltage is on and beam is on
FAULT
High voltage is off and system requires reset
Содержание 10006896
Страница 2: ......
Страница 4: ......
Страница 8: ...Model 500T2G8...
Страница 10: ......
Страница 18: ......
Страница 40: ...Model 500T2G8 28 Rev E...
Страница 44: ...Model 500T2G8 32 Rev E...
Страница 46: ...Model 500T2G8 34 Rev E...
Страница 50: ...Model 500T2G8 38 Rev E...
Страница 52: ...Model 500T2G8 40 Rev E...
Страница 66: ...Model 500T2G8 54 Rev E...
Страница 68: ......