Model 500T2G8
Rev E
21
To access the manual controls, remove the two 4-40 screws securing the emergency switch cover on the front
panel. Emergency bypass mode is selected by pushing the left-hand switch (S1) to the left. The center switch
(S2) toggles between high voltage on (left) and high voltage off (right). The right-hand switch (S3) selects
beam on in the left hand position, and beam off (RF off) in the right-hand position. There is a manual control
for the gain adjustment as well. This is a flat, square single-turn pot (R1).
CAUTION:
Do not adjust 20-turn pot R11; its function is to set the reflected RF
foldback level, and it is calibrated at the factory.
3.8 REMOTE IEEE-488 OPERATION
The TWTA is provided with a communication interface that conforms electrically to the IEEE-488 standard.
It permits remote emulation of OPERATE, STANDBY, and RESET push-buttons as well as access to
parameter measurements, system faults, gain adjustment, and control unit status. The following tables
summarize the commands and the return codes.
Table 3-3. Catalog of IEEE-488 Commands
Command
Function
Units
Response format
RDSTAT
Returns status code of processing of previous command (see
Table 3-4)
STATUS=[ ]
RDFLT
Returns system fault code (see Table 3-5)
flt=[ ]
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK
Returns cathode voltage
KV
Ek=[ ]
RDEB
Returns collector voltage
KV
Eb=[ ]
RDEF
Returns heater voltage
V
Ef=[ ]
RDIF
Returns heater current
A
If=[ ]
RDIW
Returns helix current
mA
Iw=[ ]
RDTMPTWTF
Returns TWT temp (°F)
°F
TWTF=[ ]F
RDTMPTWTC
Returns TWT temp (°C)
°C
TWTC=[ ]C
RDTMPPSF
Returns power supply temp (°F)
°F
PSF=[ ]F
RDTMPPSC
Returns power supply temp (°C)
°C
PSC=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
Содержание 10006896
Страница 2: ......
Страница 4: ......
Страница 8: ...Model 500T2G8...
Страница 10: ......
Страница 18: ......
Страница 40: ...Model 500T2G8 28 Rev E...
Страница 44: ...Model 500T2G8 32 Rev E...
Страница 46: ...Model 500T2G8 34 Rev E...
Страница 50: ...Model 500T2G8 38 Rev E...
Страница 52: ...Model 500T2G8 40 Rev E...
Страница 66: ...Model 500T2G8 54 Rev E...
Страница 68: ......