Model 500T2G8
Rev E
23
Table 3-4. Catalog of Status Codes
(The
RDSTAT
command causes the TWTA to return a string in the form
STATUS=[code],
where
[code]
is
an ASCII number whose meaning is given below)
Status Code
Meaning
0
No command was given or last command was successful.
2
Last command is in process.
3
Last command failed to complete. Time-out.
10
Last command failed. Invalid command.
11
Last command failed. Data was unparseable.
20
Last set command failed. Data was beyond high limit.
21
Last set command failed. Data was beyond low limit.
22
Last set command failed. Data was out of range
23
Last set command failed. Data was wrong polarity
50
Last command failed. Local system does not have remote enabled.
51
Remote system is not ready to accept commands.
901
Assert error: invalid table argument*
902
Assert error: invalid calibration*
* Please call a service representative if you observe this error.
Table 3-5. Catalog of Fault Codes Returned by RDFLT Command
(The
RDFLT
command causes the TWTA to return a string in the form
flt=[code],
where
[code]
is an ACSII
number whose meaning is given below).
Fault Code
Meaning
0
No fault
7
System Fault
8
Heater Fault (Fil not Ready)
9
Low Line
10
Cathode overvoltage
11
Body overcurrent
12
Cathode undervoltage
15
Collector undervoltage
16
Inverter fault
17
Internal interlock open
18
Tube arc
19
TWT (hardware) overtemperature
20
Power supply (hardware) overtemperature
22
External inhibit
23
Over reflected power
26
Panel Open
27
Latched Fault
30
Grid Overvoltage
49
TWT (software) overtemperature
50
Cabinet (software) overtemperature
Содержание 10006896
Страница 2: ......
Страница 4: ......
Страница 8: ...Model 500T2G8...
Страница 10: ......
Страница 18: ......
Страница 40: ...Model 500T2G8 28 Rev E...
Страница 44: ...Model 500T2G8 32 Rev E...
Страница 46: ...Model 500T2G8 34 Rev E...
Страница 50: ...Model 500T2G8 38 Rev E...
Страница 52: ...Model 500T2G8 40 Rev E...
Страница 66: ...Model 500T2G8 54 Rev E...
Страница 68: ......