ELECTRONIC CONTROL PANEL
Page 16
DIAGNOSTICS LEVEL
Besides of all programming parameters, a series of operating
parameters can be consulted in the diagnostics level;
particularly during a service intervention, these parameters
can be helpful to identify the cause of a problem or
malfunction
Before entering the diagnostics level, make sure that the
control valve is in the service mode.
Accessing the Diagnostics level
1.
Press the
scroll
button and hold it for 5 sec until the
display shows:
2.
Within 10 sec, press the
down
button; the display will
show:
You are now in the Diagnostics level.
Press the
scroll
button to advance to the next
diagnostics parameter.
Available diagnostics parameters
Regen X days ago
: display shows number of days since
last regeneration of the system.
In Srvc
: display shows total number of days that the
system is in service.
# of Regens
: display shows the total number of
regenerations that have taken place since installation.
TotVol
: display shows the total water usage through the
system since installation.
LastRgn@:
display shows the water usage at the moment
of the last regeneration.
InstFlow
: display shows the instantaneous flow rate.
AvgVol
: display shows the average daily water usage.
Capacity
: display shows the calculated volume of
softened water between regenerations.
Hardness
: display shows the setting of the water
hardness.
Rsrv
: display shows the setting of the reserve capacity.
Regen @
: display shows the setting of the time of
regeneration.
Override
: display shows the setting of the number of days
between regenerations.
Cycle X
: display shows the setting of the length of the
corresponding regeneration cycle.
Units
: display shows that control is programmed for
Metric units.
MTR
: display shows the setting of the water meter.
Capacity
: display shows that control is programmed for
hardness setting.
Regen
: display shows the setting of the regeneration
mode.
Valve Type
: display shows the valve type setting.
MP Resets
: display shows the number of resets of the
microprocessor (
for factory purpose only
).
Memory Reset
: display shows the number of corrupt
memory start-ups (
for factory purpose only
).
EZRSDg
: display shows the software version (
for factory
purpose only
).
CapToUse:
display shows the remaining capacity.
Exiting the Diagnostics level
1.
If no button is pressed within 5 minutes, the
microprocessor will exit the diagnostics level end return
to the service mode.
2.
Press the
scroll
button repeatedly until the display
shows:
Press the
up
or
down
button to exit the
diagnostics level.
Regen XXdays ago
System Check
Exit
Содержание ProFlow
Страница 1: ...2014 Aquion Inc TM EN ProFlow Rev2014 04 Technical Manual WATER SOFTENER...
Страница 18: ...HYDRAULIC FLOW DIAGRAMS Page 18 SERVICE BACKWASH BRINE DRAW SLOW RINSE FAST RINSE REFILL...
Страница 19: ...Page 19...
Страница 26: ...EXPLODED VIEW SIMPLEX TEMPO ECO Page 26...
Страница 28: ...EXPLODED VIEW DUPLEX ECO ALTERNATING Page 28...
Страница 30: ...EXPLODED VIEW DUPLEX ECO PARALLEL Page 30...
Страница 32: ...EXPLODED VIEW TRIPLEX ECO PARALLEL Page 32...
Страница 34: ...EXPLODED VIEW TIMER HEAD SIMPLEX Page 34...
Страница 36: ...EXPLODED VIEW TIMER HEAD DUPLEX ALTERNATING Page 36...
Страница 38: ...EXPLODED VIEW TIMER HEAD DUPLEX TRIPLEX PARALLEL Page 38...
Страница 40: ...EXPLODED VIEW VALVE BODY Page 40...
Страница 45: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 1 2 a 2 b 3 a 3 b...
Страница 46: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 4 a 4 b r 5 a 5 b...
Страница 47: ...2013 Aquion Inc PP ProFlow Rev2014 01 6 7 a 7 b r 8 a 8 b...
Страница 48: ...2013 Aquion Inc PP ProFlow Rev2014 01 r 9 10 r 11 r 12...
Страница 49: ...2013 Aquion Inc PP ProFlow Rev2014 01 13 14 a 14 b 14 c...
Страница 50: ...2013 Aquion Inc PP ProFlow Rev2014 01 15...
Страница 51: ...2013 Aquion Inc PP ProFlow Rev2014 01...
Страница 52: ...2013 Aquion Inc PP ProFlow Rev2014 01...