8
Installation
5.
Connect the Pump (G) onto the Reactor Column (C) using the compression ring by turning the
ring clockwise onto the threads.
6.
Once the Pump (G) in mounted to the Reaction Column (C), the Venturi Injector (L) should be
in a vertical position as shown in Figure 2.
7.
Attach the Drain Tube (E) to the Support Base (A) and tighten the compression ring as shown
in Figure 2.
8.
Attach the Drain Spillway (H) on the top of the Drain Tube (E).
9.
Slip the Filter Sock (M) through the Drain Spillway (H) and place the Sponge (I) on top of the
drain hole.
10. Attach the Tubing (N) at the attachment point N.2 to the Venturi Injector (L).
11.
Attach the other end of Tubing (N) to the bottom of the Air Silencer (F) as shown in Figure 2.
12.
The Air Silencer (F) can then be hung in a variety of positions on the Drain Spillway (H)
utilizing the mounting post of the Air Silencer (F)
13.
Insert the Water Control Screw (K) into the Venturi Injector (L) lightly so as to leave the flow
open.
14.
Place the Collection Cup (D) securely on top of the Reaction Column (C) as shown in Figure 2
Place the skimmer inside of the aquarium system’s sump in an accessible and convenient
position for regular maintenance and cleaning and also preferably near where water comes into
the sump from the aquarium.
The design of the division™ skimmer offers various positioning options to optimize space by
rotating the Drain Tube (E), Drain Spillway (H) or the Collection Cup (D).
For initial setup please follow these steps making sure that the aquarium’s sump is at its
appropriate water level first:
After placing the skimmer in the aquarium’s sump as above, orient the Drain Spillway (H) such
that it flows water away from the Pump (G).
1.
Remove the Collection Cup (D).
2.
Check and adjust as necessary the Water Control Screw (K) of the Venturi Injector (L) on the
Pump (G) and the Air Intake Screw (F.1) of the Air Silencer (F) so that they are fully open.