Aquatica Digital AQUATICA A300 Скачать руководство пользователя страница 9

 
Before closing the housing always ensures that: 

 
1. 

The main O-ring on the front half of the housing is clean, lubricated and properly seated for a positive seal. 

 
2. 

The sealing surface on the rear half of the housing is clean and free from any scratches or physical damage. 

 
3. 

All cords or wires are tucked in so that they do not interfere with the closing of the housing. 

 
4. 

The Function dials Knob on the rear half of housing is pulled out to allow clearance when closing the 
housing. 

 

To close the housing simply: 

 
I. 

Join the front and rear halves of the housing using the two dowel pins at the bottom of the housing as a 
guide.  

 
ii. 

Hold the housing with both hands and look around the sealing surface to ensure that the O-ring remained 
properly seated and that no cords, wires or "D-rings" are caught between the edges. 

 
iii. 

Close the two latches simultaneously. CAUTION: if you feel any resistance as you attempt to close the 
latches, do not force the closure. Check for an obstruction and try again.  

 
iv. 

Verify that the safety locking mechanisms of the latches are properly engaged to avoid any accidental 
opening. 

 

LENS INSTALLATION  

 
With the camera inside the housing, install the lens prepared with the gears through the port opening in the front of 
the housing. Ensure that the lens mounted gears are properly installed and aligned. Rotate the focus control knobs to 
ensure that the gears are properly meshed, do not grind and that their rotation is smooth. 
 
Note: to avoid breaking the auto-focus mechanism of the camera you should set the Focus Control to “M” Manual 
before testing the proper meshing of the gears. 
 
CHANGING A LENS (REMOVING A LENS) 
 
The lens mounted gears may restrict the view and ease of access to the lens release button of camera. A stick or a 
pencil can be used to push the lens release button on the camera body 
 

MOUNTING THE PORT 

 
Before mounting the Port on the Housing always ensures that;  
 
• 

The port O-ring is clean, lubricated and properly seated in its groove. 

 
• 

The sealing surface on the Housing is clean and free of physical damage. 

 

The AQUATICA A300 Housing System features a bayonet mount. To mount the port or extension ring simply: 

 
1. 

Place the housing on its back on a soft steady surface. 

 
2. 

Place the port or extension ring inside the main port of the housing. Align one of the four alignment notches 
with the opening of the housing. 

 
3. 

Place your hands on opposite sides of the port or extension ring. 

Содержание AQUATICA A300

Страница 1: ...ntinuing relationship with the most demanding underwater photographers in the world Each housings is handcrafted quality checked and pressure tested to 300 feet by a small group of specially trained i...

Страница 2: ...pressure build up inside the housing will exaggerate the force of the latch spring Keep fingers away from the path of the latches Whenever changing ports or O rings perform a simple seal test with ou...

Страница 3: ...S REAR VIEW OF THE AQUATICA A300 9 MOUNTING HOLES FOR ACCESSORY BRACKETS 10 LATCHES 11 VIEWFINDER 12 TOP WINDOW 13 AE FE LOCK CONTROL KNOB 14 AF POINT SELECTOR CONTROL BUTTON 15 LCD PANEL ILLUMINATION...

Страница 4: ...lease B Main Dial C Mode Dial D Focus and or Zoom E AE FE control D AF point selection E LCD illumination F Exposure Compensation or Aperture Value G ISO H White balance I Menu J Jump function K Playb...

Страница 5: ...comfort of handling 9 MOUNTING HOLE these are 1 4 20 TPI holes that are ready to accept TLC Base Brackets or TLC Base Ball for strobe arms or accessories 11 VIEWFINDER A full view of the illuminated c...

Страница 6: ...r you ve decided to shoot macro or wide angle photography you will be installing either the flat Macro Port acrylic port product 18426 or glass port product 18427 or 8 Dome Port Product 18405 or 6 Dom...

Страница 7: ...ance 2 Mount the focus gear over the focus ring of the lens such that the round indentation etched on the side of the gear is facing the rear of lens and is aligned with the Distance Index of the lens...

Страница 8: ...secured against rotation or movement See picture A B Align the Tripod Socket of the camera with the mounting screw Tighten the mounting screw securely with a coin or screw driver while ensuring that t...

Страница 9: ...NS INSTALLATION With the camera inside the housing install the lens prepared with the gears through the port opening in the front of the housing Ensure that the lens mounted gears are properly install...

Страница 10: ...a small dive light or a strobe arm The AQUATICA A300 Digital housing is fitted with a Standard Nikonos TTL or double TTL When using the Standard Nikonos sync cord make sure to lubricate the O ring on...

Страница 11: ...at ropes of other equipment stay clear of the system When photographing be sure to respect the environment Avoid damaging marine life or manipulating sea creatures to obtain a pleasing photo The housi...

Страница 12: ...ll not seriously impair image quality Internal scratches air side must be avoided as they do not fill in with water and will affect the quality of the image Clean the dome using only products recommen...

Страница 13: ...ring place the entire O ring over the groove and start by pushing the O ring in at each corner then push the O ring at each side and finally work in the rest of the O ring Never start at one end and w...

Отзывы: