FOCUS MODE 

 
Make sure to select the focus mode (manual or auto focus) on your camera prior to the dive. The location of the 
MF/AF selector on the lens prevent access trough the AQUATICA A300 Digital housing. 
 
AF: The camera will find, lock and hold focus as long as the shutter trigger is partially depressed. 
 
MF: You need to manually adjust the focus.  The green dot in the information bar of the camera’s viewfinder 
indicates the proper focus setting for the target subject. 
 
For more detailed information concerning the operation of the different focus modes consult the Canon 300D / 
Digital Rebel instruction book. 
 
 
U

SING THE HOUSING 

 
Whenever changing ports or O-rings, it is highly advisable to perform a simple seal test without the camera inside.  
Strapping a weight to the housing and lowering the unit to a depth of 30 to 50 feet of water for at least 10 minutes 
will assure you that the seating of the new port or o-ring is proper.  This test, though time consuming and often 
considered unnecessary, may save your camera equipment from irreparable water damage. The housing is now ready 
for the dive. 
 

CAUTION: 

Never jump into the water with the housing.  It is best to have the system handed to you after you have made your 
entry, or have it lowered to you on a rope.  Make certain that ropes of other equipment stay clear of the system. 
 
When photographing, be sure to respect the environment.  Avoid damaging marine life or manipulating sea creatures 
to obtain a pleasing photo.  The housing is slightly negatively buoyant so that you can lay it down on the bottom, but 
avoid laying it on living coral or other delicate marine life. 
 
Changing the memory card  
 
Always take care to thoroughly dry the housing before opening it to replace the memory card. Wipe the housing off 
with a dry towel. If possible it is suggested that the housing be blown dried by directing an air nozzle around the 
main o-ring before opening. 
 
Rest the housing on its front with the lens facing down (a dome shade is recommended to protect the acrylic dome 
from scratches), release the two latches simultaneously.  Lift the rear part of the housing and place it in a secure 
location.  This minimizes the possibility of any residual water falling into the housing and on to the camera when the 
housing is opened or damage to the sealing surface. 
 

TRANSPORTING THE AQUATICA A300 

 
Store the AQUATICA A300 Digital housing in a sturdy, shock proof container. 
 
When travelling by air, remove or loosen the port. This allows for equalization of the air pressure inside the housing 
to the external air pressure.  Failure to do so may cause serious damage to the acrylic ports.  Avoid travelling with the 
camera mounted in the housing.  If you must do so, remove the lens as external pressure can damage the camera. 
 

 
 
 
 
 
 

Содержание AQUATICA A300

Страница 1: ...ntinuing relationship with the most demanding underwater photographers in the world Each housings is handcrafted quality checked and pressure tested to 300 feet by a small group of specially trained i...

Страница 2: ...pressure build up inside the housing will exaggerate the force of the latch spring Keep fingers away from the path of the latches Whenever changing ports or O rings perform a simple seal test with ou...

Страница 3: ...S REAR VIEW OF THE AQUATICA A300 9 MOUNTING HOLES FOR ACCESSORY BRACKETS 10 LATCHES 11 VIEWFINDER 12 TOP WINDOW 13 AE FE LOCK CONTROL KNOB 14 AF POINT SELECTOR CONTROL BUTTON 15 LCD PANEL ILLUMINATION...

Страница 4: ...lease B Main Dial C Mode Dial D Focus and or Zoom E AE FE control D AF point selection E LCD illumination F Exposure Compensation or Aperture Value G ISO H White balance I Menu J Jump function K Playb...

Страница 5: ...comfort of handling 9 MOUNTING HOLE these are 1 4 20 TPI holes that are ready to accept TLC Base Brackets or TLC Base Ball for strobe arms or accessories 11 VIEWFINDER A full view of the illuminated c...

Страница 6: ...r you ve decided to shoot macro or wide angle photography you will be installing either the flat Macro Port acrylic port product 18426 or glass port product 18427 or 8 Dome Port Product 18405 or 6 Dom...

Страница 7: ...ance 2 Mount the focus gear over the focus ring of the lens such that the round indentation etched on the side of the gear is facing the rear of lens and is aligned with the Distance Index of the lens...

Страница 8: ...secured against rotation or movement See picture A B Align the Tripod Socket of the camera with the mounting screw Tighten the mounting screw securely with a coin or screw driver while ensuring that t...

Страница 9: ...NS INSTALLATION With the camera inside the housing install the lens prepared with the gears through the port opening in the front of the housing Ensure that the lens mounted gears are properly install...

Страница 10: ...a small dive light or a strobe arm The AQUATICA A300 Digital housing is fitted with a Standard Nikonos TTL or double TTL When using the Standard Nikonos sync cord make sure to lubricate the O ring on...

Страница 11: ...at ropes of other equipment stay clear of the system When photographing be sure to respect the environment Avoid damaging marine life or manipulating sea creatures to obtain a pleasing photo The housi...

Страница 12: ...ll not seriously impair image quality Internal scratches air side must be avoided as they do not fill in with water and will affect the quality of the image Clean the dome using only products recommen...

Страница 13: ...ring place the entire O ring over the groove and start by pushing the O ring in at each corner then push the O ring at each side and finally work in the rest of the O ring Never start at one end and w...

Отзывы: