TO SERVICE O-RINGS 

Of the housing Main O-Ring, Ports and Extension Rings 
 
1. 

Remove the O-ring.  It is important never to use a sharp instrument when removing an O-ring as this may 
damage the O-ring groove or the O-ring itself.  A bobby pin or edge of a credit card works well. 

 
2. 

Once the O-ring is removed, it should be examined for damage. Check to make sure that the O-ring is free 
of nicks and cuts and that it retains its original round profile. O-rings that appear to be damaged should be 
discarded immediately and replaced with new O-rings. 

 
3. 

Rinse the O-ring with fresh water and dry it with a clean lint free cloth. 

 
4. 

Clean the O-ring groove (where the O-ring sits) with a Q-tip. Be sure to remove any lint the Q-tip may leave 
behind. Inspect the groove for damage. 

 
5. 

Wipe the part of the housing that the O-ring seals against with a clean lint-free cloth. 

  
6. 

Re-grease the O-ring with a thin layer of O-ring grease until it appears to be smooth and shiny. Do not over 
grease it.  Use just enough grease so the O-ring will pull smoothly through your fingers.  Excessive amounts 
of grease will only serve to attract dirt to the o-ring. 

 
7. 

Make sure that the O-ring is properly (evenly) installed in the O-ring groove. 

 
8. 

To reinstall the clean and lubricated O-ring, place the entire O-ring over the groove and start by pushing the 
O-ring in at each corner then, push the O-ring at each side and finally, work in the rest of the O-ring.  Never 
start at one end and work your way around the O-ring.  This places uneven tension on the O-ring which may 
cause the O-ring to stretch resulting in excess O-ring, which will have no place to go. 

 
There are internal O-rings on the housing controls as well. These O-rings are not as susceptible to damage as they are 
not exposed but they do require yearly maintenance and are not user serviceable.  The housing should be returned to 
AQUATICA or to an authorized AQUATICA service facility for this annual maintenance.   
Check the Web site www.aquatic.ca for the closest service center. 
 
An internal moisture alarm is available for your AQUATICA A300 housing (Product # 18796).  This alarm is 
available through your authorized AQUATICA dealer and can be easily installed. 
 
 
 

WARRANTY 

 
All AQUATICA products are guaranteed against defects in material or workmanship for (1) one full year from the 
date of purchase for consumer use. These same products when used commercially will carry a 90-day warranty. No 
statutory warranty applies. Camera housed in AQUATICA housings are not covered under this warranty and 

ANY 

WATER DAMAGE SUSTAINED DUE TO INSTALLATION ERROR OR FOR ANY OTHER REASON IS 
NOT THE RESPONSIBILITY OF AQUATICA

. Therefore the appropriate insurance should be maintained by the 

user" 

Содержание AQUATICA A300

Страница 1: ...ntinuing relationship with the most demanding underwater photographers in the world Each housings is handcrafted quality checked and pressure tested to 300 feet by a small group of specially trained i...

Страница 2: ...pressure build up inside the housing will exaggerate the force of the latch spring Keep fingers away from the path of the latches Whenever changing ports or O rings perform a simple seal test with ou...

Страница 3: ...S REAR VIEW OF THE AQUATICA A300 9 MOUNTING HOLES FOR ACCESSORY BRACKETS 10 LATCHES 11 VIEWFINDER 12 TOP WINDOW 13 AE FE LOCK CONTROL KNOB 14 AF POINT SELECTOR CONTROL BUTTON 15 LCD PANEL ILLUMINATION...

Страница 4: ...lease B Main Dial C Mode Dial D Focus and or Zoom E AE FE control D AF point selection E LCD illumination F Exposure Compensation or Aperture Value G ISO H White balance I Menu J Jump function K Playb...

Страница 5: ...comfort of handling 9 MOUNTING HOLE these are 1 4 20 TPI holes that are ready to accept TLC Base Brackets or TLC Base Ball for strobe arms or accessories 11 VIEWFINDER A full view of the illuminated c...

Страница 6: ...r you ve decided to shoot macro or wide angle photography you will be installing either the flat Macro Port acrylic port product 18426 or glass port product 18427 or 8 Dome Port Product 18405 or 6 Dom...

Страница 7: ...ance 2 Mount the focus gear over the focus ring of the lens such that the round indentation etched on the side of the gear is facing the rear of lens and is aligned with the Distance Index of the lens...

Страница 8: ...secured against rotation or movement See picture A B Align the Tripod Socket of the camera with the mounting screw Tighten the mounting screw securely with a coin or screw driver while ensuring that t...

Страница 9: ...NS INSTALLATION With the camera inside the housing install the lens prepared with the gears through the port opening in the front of the housing Ensure that the lens mounted gears are properly install...

Страница 10: ...a small dive light or a strobe arm The AQUATICA A300 Digital housing is fitted with a Standard Nikonos TTL or double TTL When using the Standard Nikonos sync cord make sure to lubricate the O ring on...

Страница 11: ...at ropes of other equipment stay clear of the system When photographing be sure to respect the environment Avoid damaging marine life or manipulating sea creatures to obtain a pleasing photo The housi...

Страница 12: ...ll not seriously impair image quality Internal scratches air side must be avoided as they do not fill in with water and will affect the quality of the image Clean the dome using only products recommen...

Страница 13: ...ring place the entire O ring over the groove and start by pushing the O ring in at each corner then push the O ring at each side and finally work in the rest of the O ring Never start at one end and w...

Отзывы: