background image

W A T E R G A R D E N I N G   T O   T H E   M A X

A Q U A T E C E Q U I P M E N T. C O M

SUBMERSIBLE 

WATER PUMPS

DESIGN HIGHLIGHTS

The PondMAX EvoII Submersible Pumps have been manufactured with advanced technology to provide you with the 
best quality pumps for your pond or water feature. Visit our website to view our range of pond filtration, outdoor/
underwater lighting, water treatments and general accessories.

BENEFITS INCLUDE

•  Variable Frequency Motor Technology – Extra high 

speed rotations of impellor.

•  Open Vane Impellor Design – Handles large particles 

size up to 4mm soft sediment. 

•  Long life Impellor Design – Ceramic shaft is wear 

resistant and self-lubricated by water

•  High Head Pressure – Due to extra high speed rotations 

of impellor. 

•  Energy Efficient – Exceptional low power consumption 

to high water flow conversion. 

•  Eco Friendly – Exceptional low dB noise rating with low 

mechanical vibration. 

•  Marine Compatible* see warranty disclaimer 

– No exposed copper.

•  Tool-less Assembly - For Easy maintenance. No special 

tools required. 

•  Rotor Stop Protection – Sensors automatically cut 

power in the event that the impellor stops rotating, 
reducing the chances of motor burnout.

•  Soft Start – Rotor starts at low speed and increases 

over a short period of time. This reduces sudden recoil 
kick back on start up.

•  PondMAX Fountain & Pond pumps are suitable for 

use in many different applications including fountains, 
water features, aquatic systems, aquarium applications 
and hydroponics. The pumps can be used in either 
submersible or in-line use applications.

•  Submersible pumps are a magnetically driven 

centrifugal pump, therefore they cannot suck from 
a water level that is below the inlet level when used 
in-line. 

•  Your pump has a single moving part (an impellor set) 

enabling easy cleaning and maintenance.

•  The models EV1900 – EV13600 Pumps have intelligent 

circuitry that analyses the speed and torque of the 
motor. It will increase and decrease the energy usage to 
maximise efficiency. 
 
The soft start nature of the system helps to avoid 
sudden jolting at start up. The intelligent system will 
change the motor speed to maximise the flow of water 
in the given circumstances. If the Impellor gets jammed 
or stops, the circuitry will sense the state and cut the 
power automatically for 3 seconds and then power up 
again. 
 
This procedure will repeat 3 times. If the rotor is still 
jammed, it will activate a prolonged low state, till the 
pump is turned off, and adequate maintenance is 
carried out. Thus minimising motor burnout, due to 
electrical heat, through lack of water flow through the 
motor. 

•  The motor and electrical components are totally 

encapsulated in epoxy resin, ensuring safe operation 
under water.

•  The pump has a robust bearing and shaft design so no 

Oil/grease lubrication is required.

•  PondMAX pumps, that have plastic impeller parts and 

ceramic shafts, can be used in Marine applications as 
there is no exposed copper. For Marine use, please see 
warranty disclaimer. 

•  PondMAX Submersible Pumps are continuous rated 

therefore are designed to operate 24/7.

•  An optional fountain kit can be purchased and fitted 

to the models EV650 – EV4900 pumps. Some of 
these models include a sponge pre-filter that assists in 
straining the partials in the water, to assist the fountain 
nozzles becoming blocked up with debris. See your 
retailer for options. 

PMAX EVOII 1900_2900_3900_4900 Pump Instructions.indd   3

7/11/17   7:52 am

Содержание PONDMAX EV1900

Страница 1: ...300 AQUATEC VERSION JUNE 2016 MODEL 02EV105 EV1900 02EV125 EV2900 02EV155 EV3900 02EV175 EV4900 SUBMERSIBLE WATER PUMP INSTRUCTION MANUAL PMAX EVOII 1900_2900_3900_4900 Pump Instructions indd 1 7 11 1...

Страница 2: ...BUSH 1 1 2 TO 1 ADAPTOR Yes Yes Yes Yes THREADED BALL JOINT OUTLET 1 1 2 MALE BSP Yes Yes Yes Yes CABLE LENGTH M 10 10 10 10 RECOMMENDED TUBING SIZE MM ID 20 20 25 32 RECOMMENDED FOUNTAIN KIT 30 Jet K...

Страница 3: ...nnot suck from a water level that is below the inlet level when used in line Your pump has a single moving part an impellor set enabling easy cleaning and maintenance The models EV1900 EV13600 Pumps h...

Страница 4: ...cut the cable as this will result in voiding your warranty Care should be taken to arrange the power cable so that it cannot be accidentally tripped over or pulled Do not attempt to repair the electr...

Страница 5: ...purpose of these guidelines a PondMAX 30 Jet kit has been selected The installation principle will be similar for the other types Using the 1 to threaded reducing nipple 1 attach onto the Male Threade...

Страница 6: ...e to your desired location CLEANING INSTRUCTIONS Begin by ensuring that the mains power supply is disconnected before attempting any maintenance or adjustment of the unit or the water body Remove the...

Страница 7: ...is carried out regularly as the cooling path inside the motor will become clogged If the impellor assembly becomes worn or damaged it should be replaced available from your dealer or special orders F...

Страница 8: ...juster EV1900 EV4900 Blanking Cap for Hole in Front Filter Screen optional 1 Threaded Bush for optional Pre filter Bio sponge Threaded Hosetail for Inlet 1 BSP to 25mm Tube Impellor Cover Housing Impe...

Страница 9: ...12EV033 12EV034 12EV035 10 Sliding Base with Rubber Feet 11 Pump Motor Body 12 Reducing Bush 1 to 1 1 2 BSP Threaded 12EV018 13 O ring for Ball Joint and Hosetails Red 12EV021 x2 14 Uni directional Ba...

Страница 10: ...erwater then plug in Refill if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the block...

Страница 11: ...er Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or repl...

Страница 12: ...HOTLINE 1300 AQUATEC PMAX EVOII 1900_2900_3900_4900 Pump Instructions indd 12 7 11 17 7 52 am...

Отзывы: