background image

W A T E R G A R D E N I N G   T O   T H E   M A X

A Q U A T E C E Q U I P M E N T. C O M

WATERFEATURE PLUMBING GUIDE

If used to supply water to a waterfeature, cascade, waterfall, ect; where a pipe is needed to be used, use the hosetails 
supplied in the package.

•  For best results, use the bigger tubing size 

recommended in the table previously. Depending on 
the pump size, select the hose tail requiered for your 
tubing size and evaluate whitch step on the hose tail 
will be used. If you are using 32mm hose and you 
are connecting it to the 32mm\25mm\20mm hose 
tail supplied, remember to saw off the smaller size 
connection (I.E.: 25mm\20mm step). Otherwise it will 
create a unnessary restriction in the plumbing system. 

•  A omni-directional ball joint is provided for your 

convenence when used under water. This is because 
the diagonal side sections of the balljoint may seep 
water when under pressure. Select the 1 ½” Threaded 
Reducing adaptor and screw onto the top of the pump. 
To seal adequitly, the use of thread seal tape on this 
male thread may be requierd (availible at your local 
stockest).

•  The fittings pack should include the nessary O’ring 

washers. Select the one that will fit the female 
connection of the balljoint. Place it firmly in the locking 
nut. Now screw the locking nut of the balljoint onto the 
Threaded Addaptor on the pump. Fasten firmly but do 
not over tighten. 

•  Then select the Hose tail. Locate the second O’ring 

washer and the locking nut of the hose tail. Slide the 
loking nut over the hose tail and insert the second 
O’ring in the nut. Then connect the 1 ½” Threaded 
Locking Nut on the Hosetail to the Balljoint and screw 
in firmly. 

•  Now connect the tubing to the hose tail. Remember 

to use Stainless Stell hose clamps to fasten the hose 
on to the hosetail. This is to ensure that the pipe does 
not blow off at a later time or leak at this point in the 
plumbing system. 

•  When used in a pond/waterfeature enviroment, 

position the pump as outlined above. 

•  Direct the hose to your desired location. 

CLEANING INSTRUCTIONS 

Begin by ensuring that the mains power supply is disconnected before attempting any maintenance or adjustment of 
the unit or the water body. Remove the unit from the water. If your unit is connected to a sponge filter, the filters and 
sponges will clog up over time. Please clean regularly (at least once a month) to ensure strong water flow. Failure to 
maintain the unit will result in a burnt out motor and other damage.

•  All EvoII Submersible pumps are water cooled, if pump 

becomes restricted, or blocked, it will overheat and 
could cause permanent damage.

•  The motor unit of the pump is encapsulated with 

epoxy resin and does not need lubrication. Regular 
inspections, cleaning and maintenance of impellor is 
necessary to ensure longer life. In the centre of the 
impellor you may notice a small whole opening that 
protrudes through the ceramic shaft from front to back. 
It is paramount that this portal is kept unblocked at all 
times. This is a cooling channel for the motor. 

•  If using a fountain kit, take off the fountain set first by 

unscrewing it from the top of the pump. Examine the 
nozzles to ensure all ports are unblocked. Clean with a 
suitable brush if necessary.

•  Maintain the filter sponge regularly according to how 

long it takes for the sponge to get clogged up. When 
the flow starts to be reduced, check and clean if 
necessary. 

•  To unclip the front filter cage from the front of the 

pump, twist the cage in an anti-clockwise direction and 
pull forward. See below for diagram. If available, take 
out the optional Internal Bio sponge and clean. If using 
an optional pre-filter block sponge, slide the sponge 
off the threaded core and wash out. It is recommended 
that this is done in a bucket of pond water to ensure 
the good bacteria that are present in the sponge are 
not killed by the Chlorine in tap water. Check for wear 
and tear of the sponges. Replace if necessary.

•  You can help boost the biological function of your filter 

sponge with a bacterial additive, available from your 
local stockiest.

PMAX EVOII 1900_2900_3900_4900 Pump Instructions.indd   6

7/11/17   7:52 am

Содержание PONDMAX EV1900

Страница 1: ...300 AQUATEC VERSION JUNE 2016 MODEL 02EV105 EV1900 02EV125 EV2900 02EV155 EV3900 02EV175 EV4900 SUBMERSIBLE WATER PUMP INSTRUCTION MANUAL PMAX EVOII 1900_2900_3900_4900 Pump Instructions indd 1 7 11 1...

Страница 2: ...BUSH 1 1 2 TO 1 ADAPTOR Yes Yes Yes Yes THREADED BALL JOINT OUTLET 1 1 2 MALE BSP Yes Yes Yes Yes CABLE LENGTH M 10 10 10 10 RECOMMENDED TUBING SIZE MM ID 20 20 25 32 RECOMMENDED FOUNTAIN KIT 30 Jet K...

Страница 3: ...nnot suck from a water level that is below the inlet level when used in line Your pump has a single moving part an impellor set enabling easy cleaning and maintenance The models EV1900 EV13600 Pumps h...

Страница 4: ...cut the cable as this will result in voiding your warranty Care should be taken to arrange the power cable so that it cannot be accidentally tripped over or pulled Do not attempt to repair the electr...

Страница 5: ...purpose of these guidelines a PondMAX 30 Jet kit has been selected The installation principle will be similar for the other types Using the 1 to threaded reducing nipple 1 attach onto the Male Threade...

Страница 6: ...e to your desired location CLEANING INSTRUCTIONS Begin by ensuring that the mains power supply is disconnected before attempting any maintenance or adjustment of the unit or the water body Remove the...

Страница 7: ...is carried out regularly as the cooling path inside the motor will become clogged If the impellor assembly becomes worn or damaged it should be replaced available from your dealer or special orders F...

Страница 8: ...juster EV1900 EV4900 Blanking Cap for Hole in Front Filter Screen optional 1 Threaded Bush for optional Pre filter Bio sponge Threaded Hosetail for Inlet 1 BSP to 25mm Tube Impellor Cover Housing Impe...

Страница 9: ...12EV033 12EV034 12EV035 10 Sliding Base with Rubber Feet 11 Pump Motor Body 12 Reducing Bush 1 to 1 1 2 BSP Threaded 12EV018 13 O ring for Ball Joint and Hosetails Red 12EV021 x2 14 Uni directional Ba...

Страница 10: ...erwater then plug in Refill if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the block...

Страница 11: ...er Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or repl...

Страница 12: ...HOTLINE 1300 AQUATEC PMAX EVOII 1900_2900_3900_4900 Pump Instructions indd 12 7 11 17 7 52 am...