background image

9

59719-XXXX, 59721-XXXX, 59722-XXXX, 59722-XXXX, 59723-XXXX and 59724-XXXX

www.aquaprosystems.com

Filter Assembly

1.  Inspect and clean the tank, threads, 

and o-ring. Replace damaged parts 
as necessary.

2.  Install the drain plug in the drain 

port (or close the drain valve).

3.  Follow steps 1-12 in the “Initial  

Start-up” section of this manual.

System Inspection

The pool circulation system should be 
frequently inspected for debris and 
signs of leaks. 

 

any time the system   

  is opened, air must 

be bled from the filter using the air 
relief valve. air trapped in the system 
can cause an explosion.

1. 

Ensure pump is OFF.

 Turn off any 

automatic controls and lock out / tag 
out switches and / or circuit breakers 
to ensure the system cannot 
inadvertently turn on.

 

Verify power is  

  removed from the 

system. Disconnect, tag and lock out 
power source before attempting to 
install, service, relocate or perform any 
maintenance.

2.  Close system isolation valves, if 

installed.

3.  Remove debris from the pool 

skimmer basket.

4.  Open the air relief valve to release 

any pressure in the system.

5.  Check system for signs of leaks. If 

found, consult the owner’s manual 
of the leaking equipment.

6.  Remove pump trap cover and 

basket; remove debris. Refer to the 
pump owner’s manual for more 
specific information.

7.  Replace the pump basket and 

trap cover according to the pump 
owner’s manual.

8.  Open system isolation valves, if 

installed.

9.  With the air relief valve open, stand 

clear of the filter and start the 
pump.

10. Once a steady stream of water flows 

from the air relief valve, close the 
valve.

 

Do not over tighten  

  valve. If the valve 

fails to seal, turn the pump off, remove 
the top assembly and inspect the valve 
o-ring. reseat or replace if necessary.

11. When the system has returned to 

normal operation, check the filter 
operating pressure. If the filter 
pressure is 8 psi to 10 psi (55 kPa -  
69 kPa) above the start-up pressure, 
the filter needs to be cleaned. Refer 
to the “Cartridge Cleaning” section 
of this owner's manual (Page 8).

winterizing

Protect the filter from freezing. If 
possible, take the system indoors for 
storage.
1. 

Ensure pump is OFF.

 Turn off any 

automatic controls and lock out / tag 
out switches and / or circuit breakers 
to ensure the system cannot 
inadvertently turn on.

 

Verify power is  

  removed from the 

system. Disconnect, tag and lock out 
power source before attempting to 
install, service, relocate or perform any 
maintenance.

2.  Clean the filter. Refer to the 

“Cartridge Cleaning” section of this 
owner's manual (Page 8).

3.  Remove the filter cartridge and store 

in a warm, dry area. Protect the 
cartridge from sunlight.

4.  Cover the filter with plastic or a tarp 

to prevent water from entering the 
assembly and freezing.

 

Failure to follow  

  the above steps 

could cause the filter assembly to 
expand and crack. This will void the 
warranty.

Содержание 59719-AQP1

Страница 1: ...TAIRE l Manual del usuario 2010 59719 XXXX 59721 XXXX 59722 XXXX 59722 XXXX 59723 XXXX and 59724 XXXX 877 278 2797 fax 877 289 2963 CARTRIDGE FILTER FOR POOLS SPAS Filtre à cartouche pour piscines et spas FILTROS DE CARTUCHO PARA PISCINAS E HIDROMASAJES ...

Страница 2: ...on 65 This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling General Safety Read all manuals included with this product carefully Be thoroughly familiar with the controls and the proper use of the equipment This filter operates under high pressure Incorrectly installed or serviced equipment could ex...

Страница 3: ...diseases Consult a local pool professional for more information This filter is not designed for backwashing If unit is plumbed backwards or backwashed it will damage the filter cartridge and will void the warranty Attention Installer This manual contains important information about the installation operation and safe use of this filter This information should be furnished to the end user of this e...

Страница 4: ...20 000 27 000 75 284 45 000 60 000 94 356 34 000 45 000 Minimum Service Clearance A inches mm 38 1 4 972 38 1 4 972 38 1 4 972 45 1 2 1156 45 1 2 1156 45 1 2 1156 Filter Height B inches mm 26 5 8 676 26 5 8 676 26 5 8 676 34 864 34 864 34 864 Note Recommended Flow rate 0 5 GPM Sq Ft of filter area Actual system flow will depend on plumbing size length operating pressure bends and other system comp...

Страница 5: ...59722 XXXX 59723 XXXX and 59724 XXXX www aquaprosystems com Specifications Continued Figure 2 Piping Connections Union Coupling Filter Pump Union Coupling To Pool From Pool Outlet Inlet Union Coupling Figure 3 Filter Pressure Loss Curve ...

Страница 6: ... Valves installed near both inlet and outlet of filter will isolate the filter and ease servicing Install heater downstream of filter Install check valve between filter and heater to prevent hot water from backing up into filter if heater does not incorporate one Damage to filter modules caused by excessive heat will void the warranty A check valve installed before the filter inlet will prevent co...

Страница 7: ...he locking ring stationary rotate the top to point the air relief valve in a safe direction away from the pump and any other electrical components 9 Secure the locking ring by turning it clockwise until the safety latch clicks into place approximately 1 2 turn The latch should fall between the two tabs on the ring Figure 8 The ring may be slightly loose but it will tighten when the pump turns on I...

Страница 8: ...ned more frequently and thoroughly than chlorine systems PHMB based sanitizers also require the use of special PHMB cleaners Carefully follow the PHMB sanitizer cleaner manufacturer s instructions when cleaning the filter Use of any other type of cleansers with PHMB sanitizers will permanently clog the filter and will void the filter warranty 1 Follow all steps in the Filter Disassembly section of...

Страница 9: ... trap cover according to the pump owner s manual 8 Open system isolation valves if installed 9 With the air relief valve open stand clear of the filter and start the pump 10 Once a steady stream of water flows from the air relief valve close the valve Do not over tighten valve If the valve fails to seal turn the pump off remove the top assembly and inspect the valve o ring Reseat or replace if nec...

Страница 10: ... the suction trap in the pump Drain and skimmer valves are not fully open Fully open the drain and skimmer valves Piping is blocked upstream from the filter Remove the obstruction Plugged Cartridge Over time the filter media will become clogged and will not perform properly If the cartridge cannot be cleaned replace it If the cartridge needs replacement often check the following Insufficient clean...

Страница 11: ...6913 AQP1 6 Air Relief Valve Assembly Includes O rings 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 7 Filter Top 28580 AQP1 28580 AQP1 28580 AQP1 28581 AQP1 28581 AQP1 28581 AQP1 8 O Ring Kit Includes Lubricant 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 9 Filter Base 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 10 Safety Latch Assemb...

Страница 12: ... specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment dam...

Отзывы: