8

Operating Instructions and Parts List

Filter Disassembly

1. 

Ensure pump is OFF.

 Turn off any 

automatic controls and lock out / tag 
out switches and / or circuit breakers 
to ensure the system cannot 
inadvertently turn on.

 

Verify power is  

  removed from the 

system. Disconnect, tag and lock out 
power source before attempting to 
install, service, relocate or perform any 
maintenance.

2.  Close filter isolation valves, if 

installed.

3.  Open the air relief valve by turning 

it counter-clockwise two full turns. 
This will relieve pressure in the tank.

4.  Remove the drain plug (or open the 

drain valve) and drain all water from 
the tank.

5.  Press the safety latch toward the 

tank to release it from the locking 
ring.

6.  While holding the safety latch in the 

release position, turn the locking 
ring counter-clockwise to remove it 
(approximately 1/2 turn). If the ring 
is difficult to turn, tap it gently with 
a rubber mallet to overcome the 
initial resistance.

Cartridge Cleaning

When to clean the filter: The filter 
cartridge should normally be removed 
and cleaned when the pressure gauge 
reads 8 psi to 10 psi (55 kPa - 69 kPa) 
above the start-up pressure noted 
below:

Installation date:  __________________

Start-up pressure:  __________________

Cleaning pressure:  __________________
In some pools and spas, accessories 
such as fountains, waterfalls, and pool 
cleaners may be noticeably affected by 
the normal decrease in flow as the filter 
becomes dirty. If so, these systems may 
require more frequent cleaning (that is, 
at a pressure increase of less than 10 psi) 
to operate properly.

The cleaning interval is based on 
pressure rise, not on operation time.  
Different water conditions will lead to 
different cleaning intervals.

NOTE:

 To limit the down time of the 

filter, keep a second cartridge on hand. 
This will allow time to properly clean 
the cartridge and also will allow for 
immediate replacement should one 
filter cartridge fail.

 

when using PhmB 

 (polyhexamethylene 

biguanide) based sanitizers, such as 
Baquacil

®

, special care must be taken 

when cleaning the cartridge. Cartridges 
in systems using these sanitizers 
must be cleaned more frequently and 
thoroughly than chlorine systems. 
PhmB based sanitizers also require the 
use of special PhmB cleaners. Carefully 
follow the PhmB sanitizer/cleaner 
manufacturer's instructions when 
cleaning the filter. use of any other 
type of cleansers with PhmB sanitizers 
will permanently clog the filter and will 
void the filter warranty

1.  Follow all steps in the "Filter 

Disassembly" section of this manual.

2.  With drain plug removed, flush any 

foreign material from the inside of 
the tank before removing the filter 
cartridge.

3.  Allow the tank to drain.
4.  Carefully pull the cartridge straight 

up from the filter base, avoiding 
contact with the flow diverter.

5.  Using a garden hose with a nozzle, 

clean the cartridge thoroughly. 
Work from the top down, holding 
the nozzle at a 45° angle. Spray all 
the pleats, with emphasis between 
the pleats, until all dirt and debris is 
gone. Allow the cartridge to drain.

6.  For cartridges used where 

perspiration, suntan lotions, and 
other oils are present, soak the 
element for at least one hour 
(overnight is recommended) in one 
of the following:

a.  Commercial filter cleaner 

(follow the manufacturer’s 
directions)

b.  Solution of one cup (8 fl oz) 

trisodium phosphate (TSP) and 
five gallons water.

c.  Solution of one cup (8 fl oz) 

dishwasher detergent and five 
gallons of water.

7.  Thoroughly rinse the cartridge again 

to remove cleaning solution and oils.

8.  Inspect the cartridge for cleanliness 

and damage. If necessary, repeat the 
washing process. If the cartridge is 
damaged, replace it.

 

Failure to remove  

  all oils and cleaning 

solution before soaking cartridge in 
acid will permanently damage the filter 
cartridge.

9.  If the filter has a coating of algae, 

calcium carbonate (residue from 
calcium hypochlorite), iron or other 
minerals, soak the cartridge in a 
solution of one part muriatic acid 
to twenty parts water (6 fl oz per 
gallon of water) until all bubbling 
stops.

 

wear   

 rubber 

gloves, protective clothing 
and safety goggles when 
using acid. Do not add water 
to acid, as splashing of full 
strength acid could result. 
 
 

10. Thoroughly rinse the cartridge to 

remove all acid solution.

 

when this  

  procedure no longer 

adequately cleans the cartridge, discard 
the cartridge and replace it with a new 
one.

11. Carefully follow the steps in the 

“Filter Assembly” section of this 
manual.

Содержание 59719-AQP1

Страница 1: ...TAIRE l Manual del usuario 2010 59719 XXXX 59721 XXXX 59722 XXXX 59722 XXXX 59723 XXXX and 59724 XXXX 877 278 2797 fax 877 289 2963 CARTRIDGE FILTER FOR POOLS SPAS Filtre à cartouche pour piscines et spas FILTROS DE CARTUCHO PARA PISCINAS E HIDROMASAJES ...

Страница 2: ...on 65 This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling General Safety Read all manuals included with this product carefully Be thoroughly familiar with the controls and the proper use of the equipment This filter operates under high pressure Incorrectly installed or serviced equipment could ex...

Страница 3: ...diseases Consult a local pool professional for more information This filter is not designed for backwashing If unit is plumbed backwards or backwashed it will damage the filter cartridge and will void the warranty Attention Installer This manual contains important information about the installation operation and safe use of this filter This information should be furnished to the end user of this e...

Страница 4: ...20 000 27 000 75 284 45 000 60 000 94 356 34 000 45 000 Minimum Service Clearance A inches mm 38 1 4 972 38 1 4 972 38 1 4 972 45 1 2 1156 45 1 2 1156 45 1 2 1156 Filter Height B inches mm 26 5 8 676 26 5 8 676 26 5 8 676 34 864 34 864 34 864 Note Recommended Flow rate 0 5 GPM Sq Ft of filter area Actual system flow will depend on plumbing size length operating pressure bends and other system comp...

Страница 5: ...59722 XXXX 59723 XXXX and 59724 XXXX www aquaprosystems com Specifications Continued Figure 2 Piping Connections Union Coupling Filter Pump Union Coupling To Pool From Pool Outlet Inlet Union Coupling Figure 3 Filter Pressure Loss Curve ...

Страница 6: ... Valves installed near both inlet and outlet of filter will isolate the filter and ease servicing Install heater downstream of filter Install check valve between filter and heater to prevent hot water from backing up into filter if heater does not incorporate one Damage to filter modules caused by excessive heat will void the warranty A check valve installed before the filter inlet will prevent co...

Страница 7: ...he locking ring stationary rotate the top to point the air relief valve in a safe direction away from the pump and any other electrical components 9 Secure the locking ring by turning it clockwise until the safety latch clicks into place approximately 1 2 turn The latch should fall between the two tabs on the ring Figure 8 The ring may be slightly loose but it will tighten when the pump turns on I...

Страница 8: ...ned more frequently and thoroughly than chlorine systems PHMB based sanitizers also require the use of special PHMB cleaners Carefully follow the PHMB sanitizer cleaner manufacturer s instructions when cleaning the filter Use of any other type of cleansers with PHMB sanitizers will permanently clog the filter and will void the filter warranty 1 Follow all steps in the Filter Disassembly section of...

Страница 9: ... trap cover according to the pump owner s manual 8 Open system isolation valves if installed 9 With the air relief valve open stand clear of the filter and start the pump 10 Once a steady stream of water flows from the air relief valve close the valve Do not over tighten valve If the valve fails to seal turn the pump off remove the top assembly and inspect the valve o ring Reseat or replace if nec...

Страница 10: ... the suction trap in the pump Drain and skimmer valves are not fully open Fully open the drain and skimmer valves Piping is blocked upstream from the filter Remove the obstruction Plugged Cartridge Over time the filter media will become clogged and will not perform properly If the cartridge cannot be cleaned replace it If the cartridge needs replacement often check the following Insufficient clean...

Страница 11: ...6913 AQP1 6 Air Relief Valve Assembly Includes O rings 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 28585 AQP1 7 Filter Top 28580 AQP1 28580 AQP1 28580 AQP1 28581 AQP1 28581 AQP1 28581 AQP1 8 O Ring Kit Includes Lubricant 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 19079 AQP1 9 Filter Base 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 28574 AQP1 10 Safety Latch Assemb...

Страница 12: ... specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment dam...

Отзывы: