4
Operating Instructions and Parts List
Table 2: Model Specific Specifications
Model Number
59719-AQP1
59720-AQP1
59721-AQP1
59722-AQP1
59723-AQP1
59724-AQP1
Filter Area
Sq. Ft. (m
2
)
95 (8.8)
125 (11.6)
150 (13.9)
150 (13.9)
200 (18.6)
250 (23.2)
Recommended Flow*
(Residential) GPM (LPM)
[Gal Turnover 6hr/8hr]
48 (182)
[17,000/23,000]
63 (238)
[23,000/30,000]
75 (284)
[27,000/36,000]
75 (284)
[27,000/36,000]
100 (379)
[36,000/48,000]
125 (473)
[45,000/60,000]
Maximum Flow
(Residential) GPM (LPM)
[Gal Turnover 6hr/8hr]
95 (360)
[34,000/46,000]
125 (473)
[45,000/60,000]
150 (568)
[54,000/72,000]
150 (568)
[54,000/72,000]
200 (757)
[72,000/96,000]
250 (946)
[90,000/120,000]
Maximum Flow (Public)
GPM (LPM)
[Gal Turnover 6hr/8hr]
36 (136)
[13,000/17,000]
47 (178)
[17,000/23,000]
56 (212)
[20,000/27,000]
56 (212)
[20,000/27,000]
75 (284)
[45,000/60,000]
94 (356)
[34,000/45,000]
Minimum Service
Clearance** “A”
inches (mm)
38-1/4 (972)
38-1/4 (972)
38-1/4 (972)
45-1/2 (1156)
45-1/2 (1156)
45-1/2 (1156)
Filter Height “B”
inches (mm)
26-5/8 (676)
26-5/8 (676)
26-5/8 (676)
34 (864)
34 (864)
34 (864)
* Note: Recommended Flow rate = 0.5 GPM /Sq Ft. of filter area. Actual system flow will depend on plumbing size, length, operating
pressure, bends, and other system components.
** Note: Min. Service Clearance is the height required to remove the filter cartridge from the tank base for service. The height required
to just remove the top assembly is less than this height.
Specifications
COMMON SPECIFICATIONS
Maximum Operating
Pressure: . . . . . . . . . . . 50 psi (345 kPa)
Maximum Continuous Water
Temperature: . . . . . . . . . 104° F (40° C)
Relief valve
Pressure gauge
Locking ring
Safety latch
Outlet: 2 inch NPT
Inlet: 2 inch NPT
Drain: 2 inch NPT
3-1/8 inch
12-1/4 inch DIA.
6-7/32 inch
8-5/16 inch
A
B
16 -7/8 inch
Figure 1 - Filter Dimensions