AQUACLAVE Manual Flushing Membrane System
RO Membrane
Cartridge Filters
04
Cartridge Filters
Filter Description
Service Life
Stage 1
Pretreatment
This cartridge commences the treatment
process by removing suspended solids
such as dirt and rust. The other important
function is to reduce the chlorine and
organic content of the feed water
6 Months
Stage 2
Pretreatment
The purpose of this high performance
carbon filter is to further remove free
chlorine and organic content of the water.
It completes the 2 stage pretreatment of
the feed water supply.
6 Months
Stage 3
RO TFC Membrane
This specifically engineered low volume
production capacity with high rejection
TFC membrane is manufactured in the
USA. The membrane removes
approximately 99.99% of all dissolved
minerals and salts present in the feed
water supply. Production and performance
will be influenced by the chemical analysis
of the water supply.
3 Years
Stage 4
Post Carbon Filter
Organic Terminator
NSF approved. This post membrane
carbon filter is designed to remove
organic residue. It removes residual
impurities and odors from the tank and
provides a finer conditioning of pure
water.
6 Months
Stage 5
Non-organic Polishing
Cartridge
This final process addresses all non-
organic residue leaving a quality of water
that complies with
AS 2182 1998
Appendix C Quality of Feed Water for
Steam Generation
when the system is
operated in accordance with this manual.
6 Months
Carbon Filter
Carbon Filter
Post Carbon Filter
Non-organic Filter