AQUACLAVE Manual Flushing Membrane System
FAQ
13
Q:
What is the guarantee on the AquaClave® RO P5
system?
The AquaClave
®
RO P5 system (excluding filters) is guaranteed for 1
year for material and workmanship. All defective parts will be replaced
free within the first year under natural breakdown. The membrane has
one year pro-rated guarantee.
Q:
What factors affect the quantity and the quality of the
water production?
There are four major variables to consider:
1.
Pressure - The greater the water pressure, the better the water
quantity and quality produced. Water pressure of 60 PSI is ideal.
2.
Temperature - 23°C is the ideal water temperature for R.O. 5°C
water will cause the production of R.O. water to fall to half of that
at 23°C. The maximum water temperature recommended is 27°C.
3.
Total Dissolved Solids (TDS) - The higher the amount of dissolved
contaminants in the water, the lower the quantity of water produced.
A high level of TOTAL DISSOLVED SOLIDS can be overcome
with additional water pressure.
4.
Membrane - Different membranes have different characteristics.
Some produce more water than others; some have better
contaminant rejection capabiltiies; some have greater resistance
to chemical abrasion. For a longer life system include a carefully
selected low production, high rejection membrane. The Thin Film
Composite (TFC) membrane combines the best of these
characteristics and is considered the finest membrane in the world.
Q:
Can the AquaClave® system be connected to an extra
faucet?
No. This system is specifically engineered for use in the steam