Smartlog
- 28 -
- If your installation does not have a flow sensor, the next screen will configure the flow rate calculation from the information provided by
the meters.
Adjusting the unit and the storage period for
the flow rate calculation
(must be between 2 min and 60 min)
Enable this option to add an alert to the
calculated flow rate in the forward direction
Setting the threshold value (forward direction)
for sending the alert
Enable this option to add an alert to the
calculated flow rate in the reverse direction
Setting the threshold value (reverse direction)
for sending the alert
The flow rate is calculated automatically by the Smartlog using the sensor information in the following way:
Flow (m
3
/h) = (Count impulse since the last memorization x weight of the impulses) x (60 / Period of memorization in minutes)