Smartlog
- 25 -
- If your installation is equipped with a flow sensor, the next screen allows you to configure it.
Sensor serial number
Setting the unit and flow sensor data (values
at 4mA and 20mA)
Flow rate storage period
(must be between 2 min and 60 min)
Enable this option to add an alert to the
measured flow rate
Setting the threshold value for sending the
alert
- If your installation does not have a flow sensor, the next screen will configure the flow rate calculation from the information provided by
the meter.
Adjusting the unit and the storage period for
the flow rate calculation
(must be between 2 min and 60 min)
Enable this option to add an alert to the
calculated flow rate
Adjusting the threshold value
The flow rate is calculated automatically by the Smartlog using the sensor information in the following way:
Flow (m
3
/h) = (Count impulse since the last memorization x weight of the impulses) x (60 / Period of memorization in minutes)
11
12
13
14
15
11
12
13
11
12
13
14
15
11
12
13