6
6. Technical parameter
Model
AS70
AS90
AS110
AS130
AS170
AS210
AS280
AS280S
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
6.8
9.0
11.0
13.0
17.5
20.8
27.8
27.8
COP Range
14~7.4
14~7.4
14~6.9
14.5~7.1
15.6~6.9
14.6~7.0
15.8~7.2
15.6~7.1
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
4.9
6.5
7.5
8.9
12.3
14.3
18.8
18.8
COP Range
7.2~4.4
7.3~4.7
7.3~4.6
7.5~4.9
7.7~4.9
6.9~4.9
7.8~4.9
7.8~4.9
TECHNICAL SPECIFICATIONS
Advised pool volume (m
3
)
15~30
20~45
30~55
35~65
40~80
50~95
60~120
60~120
Operating air temperature (
℃
)
-10
℃
~43
℃
Power supply
230V 1PH
400V 3ph
Rated input power (kW)
0.14~1.12
0.19~1.38
0.22~1.63
0.26~1.82
0.32~2.51
0.38~2.92
0.5~3.84
0.5~3.84
Rated input current (A)
0.63~4.83
0.83~5.98
0.96~7.09
1.13~7.83
1.39~10.9
1.65~12.7
2.17~16.7
0.72~5.56
Power cord (mm²
)
3X1.5
3X2.5
3X2.5
3X2.5
3X4
3X4
3X6
5X2.5
Sound level at 10m dB(A)
16.5~26.0
16.8~26.1
16.6~27.9
20.1~28.7
21.1~31.8
18.9~32.2
21.5~32.9
21.5~32.9
Advised water flux (m³/h)
2~4
2~4
3~5
4~6
6~8
8~10
10~12
10~12
Water connection (mm)
50
Remarks:
This heat pump is able to perform normal within air temp -10
℃~
+43
℃
, efficiency will not be guaranteed
out of this range. Please take into consideration that the pool heat pump performance and parameters
are different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
Содержание AS110
Страница 1: ...aquaheat INVERTER POOL HEAT PUMP USER MANUAL ...
Страница 2: ......
Страница 24: ...21 J Wi Fi Operation ...
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ...AQ00ASC R32 P5 ...