background image

2

S

afety

 G

uidelineS

This manual contains very important information. 

This information will help ensure SAFETY and 

PREVENT EQUIPMENT PROBLEMS. Use these 

symbols to understand safety guidelines.

DANGER

DANGER INDICATES AN 

IMMINENTLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN 

DEATH OR SERIOUS INJURY.

WARNING INDICATES A 

POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN 

DEATH OR SERIOUS INJURY.

CAUTION INDICATES A 

POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN 

MINOR OR MODERATE INJURY.

NOTICE INDICATES IMPORTANT 

INFORMATION, THAT IF NOT 

FOLLOWED, MAY CAUSE DAMAGE TO EQUIPMENT.

WARNING

CAUTION

NOTICE

Notes

d

eScription

Aquafog CRSM mobile units are intended to condition 

large volumes of air by atomizing chemical and water 

mixtures in air temperatures between 31º and 145ºF. 

Any other use of these units will void the warranty 

and the manufacturer will not be responsible for 

problems or damages resulting from misuse.

General Safety   . . . . . . . . . . . . . . . . . . . . . . . .
Getting Started  . . . . . . . . . . . . . . . . . . . . . . . . 
Controls/ Installation  . . . . . . . . . . . . . . . . . . .  
Flow Rates/ Calibration  . . . . . . . . . . . . . . . . . 
Chemical Dilution   . . . . . . . . . . . . . . . . . . . . . 
Placement and Setup    . . . . . . . . . . . . . . . . . 
Treatment Procedure   . . . . . . . . . . . . . . . . . . 
Clean-up/ Maintenance     . . . . . . . . . . . . . . . 
Troubleshooting    . . . . . . . . . . . . . . . . . . 
Aquafog Fan Exploded View    . . . . . . . . 
CRSM Tank Exploded View    . . . . . . . . . 
Electrical Schematics   . . . . . . . . . . . . . . . . . . 
Warranty    . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAGE     

3

 4
 5

6
7
8
9

10

11 - 12
13 - 14

 15 - 16

17

18

t

able

 

of

 c

ontentS

Содержание XE CRSM

Страница 1: ...derstand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE Rear Feed UL and CSA Electrical Components XE CRSM MODEL 115V 60Hz 1Ph 240V 50...

Страница 2: ...INDICATES IMPORTANT INFORMATION THAT IF NOT FOLLOWED MAY CAUSE DAMAGE TO EQUIPMENT WARNING CAUTION NOTICE Notes Description Aquafog CRSM mobile units are intended to condition large volumes of air by...

Страница 3: ...EVERallowchildrenin the work area 7 Use of an extension cord for the CRSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before...

Страница 4: ...G USE OF AN EXTENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE 4 EXTENSION CORD SPECIFICATIONS FOR SINGLE FAN USE ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 2...

Страница 5: ...ds of time At the base of the plumbing is an in line strainer with a removable cap Occasionally check inside and flush any sediment from the screen The Hose Connection is used to supply fresh water to...

Страница 6: ...H The KEY is needed to make changes You will need the KEY located on the side of the electrical control box to make changes see Fig 3 Slide this key on top of the flow valve s stem see Fig 4 to make y...

Страница 7: ...ounds of chemical needed per acre B Ounces of chemical per 100 gallons of water applied by conventional spray nozzles If A Convert the pounds into ounces Divide the ounces by 4 36 43 560 sq ft per acr...

Страница 8: ...Pivot Fogging Head Up Pivot the fogging head upward into large open air space away from the foliage If greenhouse is equipped with Horizontal Airflow Fans HAF simultaneous operation of CRSM and HAFs...

Страница 9: ...ickling out of stationary blade assembly 4 In a small bucket thoroughly pre mix the chemical with some water 5 When Ready Slowly pour the pre mixed chemical into the tank s agitated water 6 Replace th...

Страница 10: ...if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up from the blades and any debris from blade passageways While cleaning inspect for irregularities o...

Страница 11: ...y closed position the automatic priming will not occur resulting in trapped air and poor inconsistent fogging output E Consistency of fogging output greatly depends on the consistency of the cleaning...

Страница 12: ...the slot betweenthemotorshaftandthestainlesssteelfaceplate Centeredintheslotareaand aimed slightly downward free from any rotational contact B Liquid not traveling through the fan blades This can be d...

Страница 13: ...ST 8 58 5 16 flat washer SST 12 114 Drain fitting nut 1 115 Drain gasket 1 116 5 16 18 finish nut SST 4 117 1 4 20 x 5 8 HH bolt SST 4 308 XE blade tip setscrew SST 3 349 5 16 brass rod 1 391 Top pivo...

Страница 14: ...p pivot plate Rear of Housing To Feed Pump 14 16 52 600 L 117 54 20 49 58 56 32 58 57 56 57 116 349 403 391 392 56 394 395 32 479 20 600 R Motor s Junction Box 576 7 523 522 35 To Circulation Pump 434...

Страница 15: ...1 84 45 71 C 72 65 295 295 W 14 65 65 84 45 198 67 65 Tank s Wall Inside Tank CRSM Tank Exploded View 232 207 86 423 423 75 171 173 143 3 8 tube fitting provided for optional connection to metering pu...

Страница 16: ...oupling 1 111 Axle SST 1 126 1 4 lockwasher SST 4 143 1 4 NPT M x 3 8 tube fitting 1 154 1 4 20 finish nut 4 155 1 4 NPT M x 1 2 compression fitting 1 156 Circulation tube 1 157 8 32 x 3 8 Phillips RH...

Страница 17: ...on Denotes Termination Note All green wires go to ground Denotes Line Connection Denotes Termination 240 Volt 1 Phase 50 Hertz Foreign N mtr FAN mtr PUMPS SPST TGS 115 VAC LINE SPST TGS On 2 4 5 1 3 8...

Страница 18: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...